Line 14: | Line 14: | ||
== Agenda == | == Agenda == | ||
− | # Cameron: [http://ace.phys.virginia.edu/HAPPEX/4506 CREX Pedestal update] and | + | # Cameron: [http://ace.phys.virginia.edu/HAPPEX/4506 CREX Pedestal update] and cross checked new maps |
# Cameron: update on respin-2 - finished setting up | # Cameron: update on respin-2 - finished setting up | ||
#* Changed from 1357 "Good" production runs to 1392 (35 net newly deemed Good runs) and updated labels in RCDB | #* Changed from 1357 "Good" production runs to 1392 (35 net newly deemed Good runs) and updated labels in RCDB | ||
− | #* Updated cuts on ~40 runs to accomplish that | + | #* Updated cuts on ~40 individual runs and the final week of cuts too, to accomplish that |
#* Improved burp cut implementation | #* Improved burp cut implementation | ||
#* Changed PMT pedestals to using beam off | #* Changed PMT pedestals to using beam off | ||
− | #* Updated BPM and BCM pedestals with most up to date bcm_an_us vs. unser reference | + | #* Updated BPM and BCM pedestals with most up to date bcm_an_us vs. unser reference ([http://ace.phys.virginia.edu/HAPPEX/4507 log]) |
#* Added respin1-based BMOD slopes and stable eigenvector inputs for subsequent eigenvector based regression | #* Added respin1-based BMOD slopes and stable eigenvector inputs for subsequent eigenvector based regression | ||
#* Added some more AT vs. main detector combos for additional AT analyses | #* Added some more AT vs. main detector combos for additional AT analyses | ||
+ | #* Test case, compare runs 6330, 6331, 6332 between respin 1 and 2 to eachother: | ||
+ | #** No change in number of events in root files | ||
+ | #** ~400 new entries pass cuts in respin2 | ||
+ | #** Change in Aq mean ~0.04 ppb for the same set of data | ||
+ | #** But 63 ppb change due to additional entries included (this was a no-Aq feedback time period, mean Aq is 1812 ppb -> 1749 ppb) | ||
+ | #** 0.2 ppm shifts in regressed mean for these 3 runs (out of ~2ppm signal ~ few percent shift - needs to be followed up on with the full datasets) | ||
== Present == | == Present == |
Latest revision as of 12:58, 1 April 2021
Back to Main Page >> PREX2_Analysis
previous meeting << >> following meeting
Logistic information
Time: Thursday, 1PM Meeting room at JLab: REMOTE ONLY
BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 International toll number: 408-740-7256 Bluejeans CODE: 402 129 576 Bluejeans link: https://bluejeans.com/402129576
Agenda
- Cameron: CREX Pedestal update and cross checked new maps
- Cameron: update on respin-2 - finished setting up
- Changed from 1357 "Good" production runs to 1392 (35 net newly deemed Good runs) and updated labels in RCDB
- Updated cuts on ~40 individual runs and the final week of cuts too, to accomplish that
- Improved burp cut implementation
- Changed PMT pedestals to using beam off
- Updated BPM and BCM pedestals with most up to date bcm_an_us vs. unser reference (log)
- Added respin1-based BMOD slopes and stable eigenvector inputs for subsequent eigenvector based regression
- Added some more AT vs. main detector combos for additional AT analyses
- Test case, compare runs 6330, 6331, 6332 between respin 1 and 2 to eachother:
- No change in number of events in root files
- ~400 new entries pass cuts in respin2
- Change in Aq mean ~0.04 ppb for the same set of data
- But 63 ppb change due to additional entries included (this was a no-Aq feedback time period, mean Aq is 1812 ppb -> 1749 ppb)
- 0.2 ppm shifts in regressed mean for these 3 runs (out of ~2ppm signal ~ few percent shift - needs to be followed up on with the full datasets)