Back to [[Main_Page|Main Page]] >> [[DAQ_Doc_Portal|DAQ Documentation Portal]] >> [[DAQ_Testing|DAQ Testing]] >> [[DAQ_Commissioning_Notes|DAQ Commissioning Notes]] | Back to [[Main_Page|Main Page]] >> [[DAQ_Doc_Portal|DAQ Documentation Portal]] >> [[DAQ_Testing|DAQ Testing]] >> [[DAQ_Commissioning_Notes|DAQ Commissioning Notes]] | ||
− | [[DAQ_Testing/20190523|Previous Day of Testing]] << >> [[DAQ_Testing/ | + | [[DAQ_Testing/20190523|Previous Day of Testing]] << >> [[DAQ_Testing/20190618|Next Day of Testing]] |
June 3rd, 2019 | June 3rd, 2019 |
Latest revision as of 01:07, 19 June 2019
Back to Main Page >> DAQ Documentation Portal >> DAQ Testing >> DAQ Commissioning Notes
Previous Day of Testing << >> Next Day of Testing
June 3rd, 2019 Testers: Cameron Clarke, Paul King
Status
- New HAPTB based VQWK timing initialization in all crates
- DAQ and Japan setup for ideal battery noise/pickup testing
- Beam sync and timing board status - update
VQWK ADC and HAPTB timing settings update
Updated vqwk_32_longcall.o and timebrd_set_scan.o in bootscripts so they now read flags files at boot to initialize and CRL doesn't change the HAPTB settings anymore (trust they are OK)
- Run 2487 tests the new timing and ADC setting technique
Timing Jitter for 120 Hz linesync
We found a potential way to lock the Raster to the HelBoard's 120Hz signal - see Helicity Control
Optimal Battery DAQ and Japan setup (from 05/23/2019)
When performing battery noise floor/crosstalk/pickup studies we want to ensure that the batteries are connected (preferably with a capacitor in the way) to the same ground as the Main detector High Voltages or to the Main detector pre-amps' outputs, or in INJ/CH floating w.r.t. the VME crate ground.
In order to analyze battery data we want to use the standard detector map (properly updated with battery and empty channels names)
detectors = prex_detectors.map
We do not want to normalize against BCMs
QwDetectorArray.normalize = 0 QwBlindDetectorArray.normalize = 0
We want to allow differences for all types of signals for comparisons
enable-differences = 1
And we want to ignore stability cuts
ring.stability_cut = 0
The form that the data takes is determined by the map files which can contain pedestals and scale factors for the data, but a raw channel with no such map file provided will be given in total integrated ADC samples/number of samples as the .hw_sum values, and as total integrated ADC samples (an integer) in the .hw_sum_raw (and .block[0,1,2,3]_raw values). These raw values are not available in the mul (pattern) tree, but can be obtained by multiplying by num_samples. As long as the pedestal maps don't give a conversion factor then the hw_sum (_raw) outputs will always be in ADC counts/sample units (ADC counts units).