Difference between revisions of "WAC Notes July 18 2019"

From PREX Wiki
Jump to navigationJump to search
Line 50: Line 50:
  
 
== Pedestal/Calibrations Updates ==
 
== Pedestal/Calibrations Updates ==
 +
 +
In order to salvage current ramps and trips on large chunks of data and save time/save the regression/pedestal usefulness:
 +
* Change the lower limit current cut to be nominal-15 uA (35 for 50 uA, 55 for 70 uA)
 +
* Updating the event cuts to have nominal-15 uA beam current lower cut Starting at run 3456 (now) and also setting specifically for 3 70 uA current ramp runs 3424, 3429, 3430 (suspect Aq, but worth a try)
 +
** 50 uA: prexCH_beamline_eventcuts.2948-.map -> prexCH_beamline_eventcuts.3456-.map
 +
** 70 uA: prexCH_beamline_eventcuts.2948-.map -> prexCH_beamline_eventcuts.[3424,3429,3430].map
  
 
== Issues ==
 
== Issues ==

Revision as of 17:39, 18 July 2019

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << Instructions

WAC Notes July 17 2019 << >> WAC Notes July 19 2019

July 18 2019 Owl Shift

70 uA production

  • Good, Current Ramp (add cut on BCM): 3424
  • 3425
  • 3426
  • 3427
  • 3427
  • Good, Current Ramp (add cut on BCM): 3428
  • Good, Current Ramp (add cut on BCM): 3429

50 uA Production

Lots of production, only 1 major problem (lost run 3533 with 9k muls due to blinder fail from EPICs fastlogger and Compton IOC)

Run list:

  • 3434
  • 3435
  • 3436
  • 3437
  • 3438
  • 3439
  • 3440
  • 3441
  • 3442
  • 3443
  • 3444
  • 3445

Production Run List (status at Midnight, end of 7/18/2019)

Non-Production Runs and Bad Runs

  • Died (blinder needs fixing): 3433

Pedestal/Calibrations Updates

In order to salvage current ramps and trips on large chunks of data and save time/save the regression/pedestal usefulness:

  • Change the lower limit current cut to be nominal-15 uA (35 for 50 uA, 55 for 70 uA)
  • Updating the event cuts to have nominal-15 uA beam current lower cut Starting at run 3456 (now) and also setting specifically for 3 70 uA current ramp runs 3424, 3429, 3430 (suspect Aq, but worth a try)
    • 50 uA: prexCH_beamline_eventcuts.2948-.map -> prexCH_beamline_eventcuts.3456-.map
    • 70 uA: prexCH_beamline_eventcuts.2948-.map -> prexCH_beamline_eventcuts.[3424,3429,3430].map

Issues

Other Status Updates