Line 20: Line 20:
 
=== Slug 5: 70 uA production ===
 
=== Slug 5: 70 uA production ===
 
Data was recovered from 3424, 3429, and 3430 current ramp runs with better beam current lower limit cut
 
Data was recovered from 3424, 3429, and 3430 current ramp runs with better beam current lower limit cut
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-18/run3424_000/run3424_000_all.pdf 3424]
+
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3424_000/run3424_000_all.pdf 3424]
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-18/run3425_000/run3425_000_all.pdf 3425]
+
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3425_000/run3425_000_all.pdf 3425]
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-18/run3426_000/run3426_000_all.pdf 3426]
+
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3426_000/run3426_000_all.pdf 3426]
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-18/run3427_000/run3427_000_all.pdf 3427]
+
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3427_000/run3427_000_all.pdf 3427]
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-18/run3428_000/run3428_000_all.pdf 3428]
+
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3428_000/run3428_000_all.pdf 3428]
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-18/run3429_000/run3429_000_all.pdf 3429]
+
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3429_000/run3429_000_all.pdf 3429]
 
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-18/run3430_000/run3430_000_all.pdf 3430]
 
* Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-18/run3430_000/run3430_000_all.pdf 3430]
  

Revision as of 19:27, 18 July 2019

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << Instructions

WAC Notes July 17 2019 << >> WAC Notes July 19 2019

July 18 2019 all 3 Shifts

Slug 5: 70 uA production

Data was recovered from 3424, 3429, and 3430 current ramp runs with better beam current lower limit cut

Slug 6: 50 uA Production

Lots of production, only 1 major problem (lost run 3533 with 9k muls due to blinder fail from EPICs fastlogger and Compton IOC)

Run list:

Slug 7: 50 uA Production

Production Run List (status at Midnight, end of 7/18/2019)

Non-Production Runs and Bad Runs

Pedestal/Calibrations Updates

In order to salvage current ramps and trips on large chunks of data and save time/save the regression/pedestal usefulness:

  • Change the lower limit current cut to be nominal-15 uA (35 for 50 uA, 55 for 70 uA)
  • Updating the event cuts to have nominal-15 uA beam current lower cut Starting at run 3456 (now) and also setting specifically for 3 70 uA current ramp runs 3424, 3429, 3430 (suspect Aq, but worth a try)

Issues

Other Status Updates

PQB runs need analyzing - see notes