Difference between revisions of "WAC Notes July 23 2019"
From PREX Wiki
Jump to navigationJump to search(12 intermediate revisions by 2 users not shown) | |||
Line 18: | Line 18: | ||
== July 23 2019 == | == July 23 2019 == | ||
− | * Slug 12 is the first without the old PREX 1 quartz - from here on we are using different quartz: [https://logbooks.jlab.org/entry/3708281 HALOG] | + | * Slug 12 is the first without the old PREX 1 quartz (in '''LHRS''') - from here on we are using different quartz: [https://logbooks.jlab.org/entry/3708281 HALOG] |
=== Production Run List === | === Production Run List === | ||
− | Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug12-Left/y_postPanPlots_slug12-Left.pdf Slug 12] at junk run 3583, [https://logbooks.jlab.org/entry/3708464 IHWP In], FFB on always, no RHRS | + | Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug12-Left/y_postPanPlots_slug12-Left.pdf Slug 12] at junk run 3583, [https://logbooks.jlab.org/entry/3708464 IHWP In], FFB on always, no RHRS, new PREX II quartz (in '''LHRS''') |
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-23/run####_000/run####_000_all.pdf ####] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-23/run####_000/run####_000_all.pdf ####] | ||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == | ||
+ | * Junk 3583: adaq1 test at midnight ('''slug12''' starts here) | ||
+ | * Junk 3584- : Test runs after '''IHWP in''' | ||
== Pedestal/Calibrations Updates == | == Pedestal/Calibrations Updates == | ||
+ | * Updated '''prex_maindet.3583-.map''' | ||
+ | ** Removed '''not_blindable''' and '''not_normalizable''' from RHRS '''MAIN''' detectors | ||
+ | ** Removed '''not_normalizable''' from RHRS '''AT''' detectors | ||
+ | * Updated '''prexCH_beamline_eventcuts.3583-.map''' for 70uA running | ||
+ | ** '''bcm, bcm_an_ds, 55, 1e6, g, 0.8''' | ||
+ | ** '''bcm, bcm_an_us, 55, 1e6, g, 0''' | ||
+ | ** all other cuts '''as of before''' | ||
+ | *Based on [https://logbooks.jlab.org/entry/3707321 HALOG] | ||
+ | ** Updated '''prexCH_beamline_pedestal.3583-.map''' | ||
+ | ** Updated '''prex_maindet_pedestal.3583-.map''' | ||
+ | ** Updated '''prex_sam_pedestal.3583-.map''' | ||
+ | *** Pedestal map files need to be updated once we have results from '''new''' current scan | ||
== Issues == | == Issues == | ||
Line 32: | Line 46: | ||
== Other Status Updates == | == Other Status Updates == | ||
* [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/Charge_Monitor-2019-07-23.pdf Accumulated charge] = | * [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/Charge_Monitor-2019-07-23.pdf Accumulated charge] = | ||
− | * Slug 12 is the first without the old PREX 1 quartz - from here on we are using different quartz: [https://logbooks.jlab.org/entry/3708281 HALOG] | + | * Slug 12 is the first without the old PREX 1 quartz in LHRS (RHRS still has old PREX 1 quartz)- from here on we are using different quartz: [https://logbooks.jlab.org/entry/3708281 HALOG] |
+ | * I was informed that the prexPrompt_pass1 root file for run 3425 was accidentally overwritten | ||
+ | ** Re-prompted this run | ||
+ | * Re-prompted [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3571_000/run3571_000_all.pdf run3571] ... the glitch is fixed, plots look ok!. The blinder is still 0'd out | ||
+ | * Re-prompted [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3573_000/run3573_000_all.pdf run3573] ... event cut applied (CodaEventNumber>132000&&CodaEventNumber<172000). | ||
[[Category:WAC]] | [[Category:WAC]] |
Latest revision as of 10:58, 24 July 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions
WAC Notes July 22 2019 << >> WAC Notes July 24 2019
July 23 2019
- Slug 12 is the first without the old PREX 1 quartz (in LHRS) - from here on we are using different quartz: HALOG
Production Run List
Start Slug 12 at junk run 3583, IHWP In, FFB on always, no RHRS, new PREX II quartz (in LHRS)
- Good - ####
Non-Production Runs and Bad Runs
- Junk 3583: adaq1 test at midnight (slug12 starts here)
- Junk 3584- : Test runs after IHWP in
Pedestal/Calibrations Updates
- Updated prex_maindet.3583-.map
- Removed not_blindable and not_normalizable from RHRS MAIN detectors
- Removed not_normalizable from RHRS AT detectors
- Updated prexCH_beamline_eventcuts.3583-.map for 70uA running
- bcm, bcm_an_ds, 55, 1e6, g, 0.8
- bcm, bcm_an_us, 55, 1e6, g, 0
- all other cuts as of before
- Based on HALOG
- Updated prexCH_beamline_pedestal.3583-.map
- Updated prex_maindet_pedestal.3583-.map
- Updated prex_sam_pedestal.3583-.map
- Pedestal map files need to be updated once we have results from new current scan
Issues
Other Status Updates
- Accumulated charge =
- Slug 12 is the first without the old PREX 1 quartz in LHRS (RHRS still has old PREX 1 quartz)- from here on we are using different quartz: HALOG
- I was informed that the prexPrompt_pass1 root file for run 3425 was accidentally overwritten
- Re-prompted this run
- Re-prompted run3571 ... the glitch is fixed, plots look ok!. The blinder is still 0'd out
- Re-prompted run3573 ... event cut applied (CodaEventNumber>132000&&CodaEventNumber<172000).