Difference between revisions of "Flipper"

From PREX Wiki
Jump to navigationJump to search
Line 10: Line 10:
  
 
Special note for slugs 24,25
 
Special note for slugs 24,25
**For slug 24 and 25 on 8/1/2019, use ./CancelPCValues  and ./checkCancelPCValues
+
** For slug 24 and 25 on 8/1/2019, use ./CancelPCValues  and ./checkCancelPCValues
 
** Then (after IHWP is in new desired state), on apar@adaq2, in ~/feedback2019/CancelFlip, run ./CancelPCValues to set the voltages correctly
 
** Then (after IHWP is in new desired state), on apar@adaq2, in ~/feedback2019/CancelFlip, run ./CancelPCValues to set the voltages correctly
 
** Double check voltages are correct: on apar@adaq2, in /feedback2019/CancelFlip, run ./checkCancelPCvalues The output should tell you the voltages are good, otherwise call an expert.
 
** Double check voltages are correct: on apar@adaq2, in /feedback2019/CancelFlip, run ./checkCancelPCvalues The output should tell you the voltages are good, otherwise call an expert.

Revision as of 20:01, 1 August 2019

  • Flip IHWP state
    • to flip IHWP state, will have to inform other halls of intention to flip state first. Then call MCC and ask them to flip state.
    • Note: After the IHWP state has been changed, the parity alarms will go off until the voltages are set correctly.
    • Then (after IHWP is in new desired state), on apar@adaq2, in ~/feedback2019, run ./FlipPCValues to set the voltages correctly
    • Double check voltages are correct: on apar@adaq2, in /feedback2019, run ./checkPCvalues The output should tell you the voltages are good, otherwise call an expert.
    • if alarms go off and values don't match those in table, call an Expert
    • Update the slug number and IHWP state of the white board, write down the time of flip and first run number for new slug.
    • Check the values against the table in Parity Checks

Special note for slugs 24,25

    • For slug 24 and 25 on 8/1/2019, use ./CancelPCValues and ./checkCancelPCValues
    • Then (after IHWP is in new desired state), on apar@adaq2, in ~/feedback2019/CancelFlip, run ./CancelPCValues to set the voltages correctly
    • Double check voltages are correct: on apar@adaq2, in /feedback2019/CancelFlip, run ./checkCancelPCvalues The output should tell you the voltages are good, otherwise call an expert.