Difference between revisions of "WAC Notes December 13 2019"

From PREX Wiki
Jump to navigationJump to search
Line 22: Line 22:
  
 
=== Production Run List - Slug 100 - pre-Production ===
 
=== Production Run List - Slug 100 - pre-Production ===
 +
 +
* Run 5408 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5408_000 plots] - Ca48 - 100uA - '''GOOD'''
 +
* Run 5409 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5409_000 plots] - Ca48 - 100uA - '''GOOD'''
 +
 +
== Non-Production Runs and Bad Runs ==
  
 
Calcium 40
 
Calcium 40
Line 33: Line 38:
 
* Run 5412 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5412_000 plots] - Ca40 - 10uA - BMOD
 
* Run 5412 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5412_000 plots] - Ca40 - 10uA - BMOD
 
* Run 5413 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5413_000 plots] - Ca40 - 140uA
 
* Run 5413 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5413_000 plots] - Ca40 - 140uA
 +
* Run 5414 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5414_000 plots] - Ca40 - DAQ test
  
 
Calcium 48
 
Calcium 48
Line 40: Line 46:
 
* Run 5406 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5406_000 plots] - Ca48 - 50uA
 
* Run 5406 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5406_000 plots] - Ca48 - 50uA
 
* Run 5407 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5407_000 plots] - Ca48 - 50uA
 
* Run 5407 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5407_000 plots] - Ca48 - 50uA
* Run 5408 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5408_000 plots] - Ca48 - 100uA
+
* Run 5415 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5415_000 plots] - Ca48 - 10 uA BeamMod commissioning
* Run 5409 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5409_000 plots] - Ca48 - 100uA
+
* Run 5416 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5416_000 plots] - Ca48 - Aq feedback failed - 90 ppm Aq
 
+
* Run 5417 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5417_000 plots] - Ca48 - Current Ramp calibrations - SAMs and maindets
 
+
* Run 5418 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5418_000 plots] - Ca48 - no beam
== Non-Production Runs and Bad Runs ==
+
* Run 5419 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5419_000 plots] - Ca48 - no beam
 
+
* Run 5420 - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5420_000 plots] - Ca48 - no beam
  
 
== Pedestal/Calibrations Updates ==
 
== Pedestal/Calibrations Updates ==
Line 72: Line 78:
  
 
=== Target/Energy Tolerances ===
 
=== Target/Energy Tolerances ===
* How much of a excursion is dangerous for Ca48 frame issues?
+
* How much of a excursion is dangerous for Ca48 frame issues? - Bob and Silviu say +-0.5 mm is still a good cut metric
 
* How well centered are we on the middle of the 9.4 mm Ca48 frame? [https://logbooks.jlab.org/entry/3752440 Beam Centering and Q^2 Log entry]
 
* How well centered are we on the middle of the 9.4 mm Ca48 frame? [https://logbooks.jlab.org/entry/3752440 Beam Centering and Q^2 Log entry]
 
* Beam Energy Fluctuation tolerances with Excited States in HRS?? - FFB fixes this? Arc 1 vs 2 energy measurements and locks?
 
* Beam Energy Fluctuation tolerances with Excited States in HRS?? - FFB fixes this? Arc 1 vs 2 energy measurements and locks?

Revision as of 15:36, 14 January 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions

WAC Notes November 27 2019 << >> WAC Notes December 14 2019

December 13 2019

Daily Meeting BlueJeans

Production Run List - Slug 100 - pre-Production

  • Run 5408 - plots - Ca48 - 100uA - GOOD
  • Run 5409 - plots - Ca48 - 100uA - GOOD

Non-Production Runs and Bad Runs

Calcium 40

  • Run 5398 - plots - Ca40 - 50uA
  • Run 5399 - plots - Ca40 - 50uA
  • Run 5400 - plots - Ca40 - 100uA
  • Run 5401 - plots - Ca40 - 100uA
  • Run 5402 - plots - Ca40 - 100uA
  • Run 5410 - plots - Ca40 - 140uA
  • Run 5411 - plots - Ca40 - 140uA
  • Run 5412 - plots - Ca40 - 10uA - BMOD
  • Run 5413 - plots - Ca40 - 140uA
  • Run 5414 - plots - Ca40 - DAQ test

Calcium 48

  • Run 5403 - plots - Ca48 - 50uA
  • Run 5404 - plots - Ca48 - 50uA
  • Run 5405 - plots - Ca48 - 50uA
  • Run 5406 - plots - Ca48 - 50uA
  • Run 5407 - plots - Ca48 - 50uA
  • Run 5415 - plots - Ca48 - 10 uA BeamMod commissioning
  • Run 5416 - plots - Ca48 - Aq feedback failed - 90 ppm Aq
  • Run 5417 - plots - Ca48 - Current Ramp calibrations - SAMs and maindets
  • Run 5418 - plots - Ca48 - no beam
  • Run 5419 - plots - Ca48 - no beam
  • Run 5420 - plots - Ca48 - no beam

Pedestal/Calibrations Updates

  • Devi has pedestals for SAMs and Main detectors - a new SAM pedestal run will need to be made with Devi's update
  • We only have a Detector calibration - Caryn
  • We need to take pedestals for BPMs - Amali

Issues

  • beam mod analyzer + plotter documentation
    • get bmod analysis results into a panguin or prompt plot
    • get bmod analysis slopes into a online japan corrector for live regressed results
  • dither correction / combiner map
  • replace aggregator folder with develop
  • make sure prex/crex data don't become mixed - fix grand agg plots
  • fix burst definition as events passing cuts instead of fixed time intervals
    • respin previous data
  • make the combiner and mulc maps up to date
    • fix missing channels and add new ones to aggregator


BCMs

  • We want to use BCM an US as our normalizer and feedback BCM
  • We need to check with Hall C and turn their feedback back on when they want it (still not 100% checked out that the EPICs print for Hall C is independent)
  • We need an Unser curent ramp to calibrate these at 150 uA - Caryn

Target/Energy Tolerances

  • How much of a excursion is dangerous for Ca48 frame issues? - Bob and Silviu say +-0.5 mm is still a good cut metric
  • How well centered are we on the middle of the 9.4 mm Ca48 frame? Beam Centering and Q^2 Log entry
  • Beam Energy Fluctuation tolerances with Excited States in HRS?? - FFB fixes this? Arc 1 vs 2 energy measurements and locks?

Commissioning needs

  • Compton Chicane
  • BMW commissioning
  • Spot size on the target minimization
  • FFB commissioning - Today day shift

Other Status Updates

BMOD Ana

note regarding beammod analysis:

Running the BeamMod analysis for a single run.

From ~/PREX/prompt/bmodAna/ create a new beammod root file from the already prompted run (####) using command root -l -b -q bmodAna.C'(####,"max_input.list")'

then, to plot all combinations of alphas, deltas,and alpha/delta use the common root -l -b -q plotAD.C'("path/to/rootfile/created/by/the/previous/command.root")

Counting Mode Downstream Detectors

  • Devi has changed DS detectors to counting mode at 5420