Difference between revisions of "WAC Notes January 11 2020"

From PREX Wiki
Jump to navigationJump to search
m
Line 15: Line 15:
 
[[Main_Page|<B>PREX Main</B>]] << [[Weekly Analysis Coordinator]] << [[WAC Notes]] << [[WAC|Instructions]]
 
[[Main_Page|<B>PREX Main</B>]] << [[Weekly Analysis Coordinator]] << [[WAC Notes]] << [[WAC|Instructions]]
 
<br><br>
 
<br><br>
[[WAC Notes January 9 2020]] << >> [[WAC Notes January 12 2020]]
+
[[WAC Notes December 15 2019]] << >> [[WAC Notes January 12 2020]]
  
 
== January 11 2020 ==
 
== January 11 2020 ==

Revision as of 16:12, 14 January 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions

WAC Notes December 15 2019 << >> WAC Notes January 12 2020

January 11 2020

Daily Meeting BlueJeans

Production Run List - Slug 106 (b) - Production

  • Good - Run 5636 - Ca48 150uA - very messy beam, otherwise OK small amount of data
  • The magnet setting splits this slug to 107

Non-Production Runs and Bad Runs

Pedestal/Calibrations Updates

Issues

  • Adjustment in LHRS dipole current messed up the detector alignment - gets its own separate slug 107 - WAC diagnostic on widths here: https://logbooks.jlab.org/entry/3761778
  • FFB was saturating all night, killing lots of our data with BPM cuts - this was due to improper limits on auto-gaining BPMs set by OPS - this made some strange noise upon FFB restoration after BMW cycles: https://logbooks.jlab.org/entry/3761789
  • Run 5646 had a LQ1 trip, cutting out events 200k and onward in that run only

BMOD Ana

note regarding beammod analysis:

Running the BeamMod analysis for a single run.

From ~/PREX/prompt/bmodAna/ create a new beammod root file from the already prompted run (####) using command root -l -b -q bmodAna.C'(####,"some_input.list")'

then, to plot all combinations of alphas, deltas,and alpha/delta use the common root -l -b -q plotAD.C'("path/to/rootfile/created/by/the/previous/command.root")

Counting Mode Downstream Detectors

  • Removed from cuts and correlator channel maps for safety