Difference between revisions of "WAC Notes February 1 2020"

From PREX Wiki
Jump to navigationJump to search
Line 25: Line 25:
  
 
=== Production Run List - Slug 122 - IHWP IN - Flip-RIGHT - Production ===
 
=== Production Run List - Slug 122 - IHWP IN - Flip-RIGHT - Production ===
continue slug 122 on [https://prex.jlab.org/wiki/index.php?title=WAC_Notes_January_31_2020 January 31]:
+
continue slug 122 from [https://prex.jlab.org/wiki/index.php?title=WAC_Notes_January_31_2020 January 31]:
  
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run6102_000 Run 6102]
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run6102_000 Run 6102]
Line 32: Line 32:
 
* Right arm only - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run6105_000 Run 6105]
 
* Right arm only - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run6105_000 Run 6105]
 
* Right arm only - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run6106_000 Run 6106]
 
* Right arm only - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run6106_000 Run 6106]
 
 
  
 
=== Production Run List - Slug 123 - IHWP OUT - Flip-RIGHT - Production ===
 
=== Production Run List - Slug 123 - IHWP OUT - Flip-RIGHT - Production ===

Revision as of 16:57, 1 February 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes January 31 2020 << >> WAC Notes February 2 2020

February 1 2020

Daily Meeting BlueJeans


Production Run List - Slug 122 - IHWP IN - Flip-RIGHT - Production

continue slug 122 from January 31:

Production Run List - Slug 123 - IHWP OUT - Flip-RIGHT - Production

start slug 123 at about 3:50 am

Non-Production Runs and Bad Runs

  • Test - Run 6117 is a test run with only 10 uA, but we can use its data, just need to modify the beamline_eventcut map file

Pedestal/Calibrations Updates

Issues

  • Since run 6099, the bcm asym is quite large (>~ 300 ppm) due to large asym in injector
  • LQ2 quenched at about 3:25 am, making run 6105 through 6110 right arm only

Updates