# Devi: PMT non-linearity bench test [http://ace.phys.virginia.edu/HAPPEX/4170 HAPLOG 4170]
 
# Devi: PMT non-linearity bench test [http://ace.phys.virginia.edu/HAPPEX/4170 HAPLOG 4170]
 
#* KP: is DAQ at the same setting as normal run? DA: Yes.
 
#* KP: is DAQ at the same setting as normal run? DA: Yes.
#* KK: Have we tried leave PMT on for a day long and performed measurement? DA: We tried hour long warming up.
+
#* KK: Have we tried leaving PMT on for a day long then performing measurement? DA: We tried hour long warming up and we have temperature sensors.
# Ciprian: Transverse asymmetry sumary
+
# Ciprian: Transverse asymmetry summary [https://docs.google.com/spreadsheets/d/1ZI68PgAn_zySKozZ__kHBvxlBmaTMKw9jPSl-EIa91k/edit?usp=sharing spreadSheet]
#* CP: we need further work to correct asymmetry sign  
+
#* CG: we need further work to correct asymmetry sign  
#* David A: is it blinded? CP: No.
+
#* David A: is it blinded? CG: No.
 
#* Devi A: the target impurity is Carbon rate divided by Pb rate
 
#* Devi A: the target impurity is Carbon rate divided by Pb rate
 
#* KK:  we can have straight average from Moller and Compton results instead of weighting average.
 
#* KK:  we can have straight average from Moller and Compton results instead of weighting average.
#* David A: is the transverse spin direction perfectly vertical? CP: based on Mott results, I think it is within 2 %.  
+
#* David A: is the transverse spin direction perfectly vertical? CG: based on Mott results, I think it is within 2 %.  
 
#* KK : We can tell this from the average.  
 
#* KK : We can tell this from the average.  
 +
#* PK : transverse spin direction will affect loss in analyzing power. KK: HRS acceptance will make difference as well.
  
 
== Present ==
 
== Present ==

Latest revision as of 17:15, 8 July 2020

Back to Main Page >> PREX2_Analysis

previous meeting << >> following meeting

Logistic information

Meeting room at JLab: REMOTE ONLY

 BlueJeans calling instructions:
 Toll-Free Number (U.S.&  Canada):  888-240-2560
 International toll number:         408-740-7256
 Bluejeans CODE: 206 308 0414                 
 Bluejeans link: https://bluejeans.com/2063080414

Agenda

  1. Devi: PMT non-linearity bench test HAPLOG 4170
    • KP: is DAQ at the same setting as normal run? DA: Yes.
    • KK: Have we tried leaving PMT on for a day long then performing measurement? DA: We tried hour long warming up and we have temperature sensors.
  2. Ciprian: Transverse asymmetry summary spreadSheet
    • CG: we need further work to correct asymmetry sign
    • David A: is it blinded? CG: No.
    • Devi A: the target impurity is Carbon rate divided by Pb rate
    • KK: we can have straight average from Moller and Compton results instead of weighting average.
    • David A: is the transverse spin direction perfectly vertical? CG: based on Mott results, I think it is within 2 %.
    • KK : We can tell this from the average.
    • PK : transverse spin direction will affect loss in analyzing power. KK: HRS acceptance will make difference as well.

Present

Ciprian G, Tao Y, Dustin M, Ezekiel W, Rober R, Jim N, Quinn C, Kent P, Guido U, Sanghwa P, Victoria O, Ryan R, Paul S, Silviu CD, Devi A, Sakib R, Siyu J, Caryn P, Weibin Z, Ye T, KK, Cameron C, Amali P, Robert M, Juliette M, Briann Q, Adam Z, Don J, David A, Hanjie L, Devika B, Paul K

Excused