Difference between revisions of "DAQ Testing/20200730"
From PREX Wiki
Jump to navigationJump to search (Created page with "Back to Main Page >> DAQ Documentation Portal >> DAQ Testing >> DAQ Commissioning Notes DAQ_Tes...") |
m |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
Back to [[Main_Page|Main Page]] >> [[DAQ_Doc_Portal|DAQ Documentation Portal]] >> [[DAQ_Testing|DAQ Testing]] >> [[DAQ_Commissioning_Notes|DAQ Commissioning Notes]] | Back to [[Main_Page|Main Page]] >> [[DAQ_Doc_Portal|DAQ Documentation Portal]] >> [[DAQ_Testing|DAQ Testing]] >> [[DAQ_Commissioning_Notes|DAQ Commissioning Notes]] | ||
− | [[DAQ_Testing/20190807|Previous Day of Testing]] << >> [[DAQ_Testing/ | + | [[DAQ_Testing/20190807|Previous Day of Testing]] << >> [[DAQ_Testing/20200804|Next Day of Testing]] |
July 30th, 2020 | July 30th, 2020 | ||
Line 9: | Line 9: | ||
* [[media:SummaryPlots_7507_testChannels.pdf|Run 7507]] - Shows channel 5_2 is bad | * [[media:SummaryPlots_7507_testChannels.pdf|Run 7507]] - Shows channel 5_2 is bad | ||
* [[media:SummaryPlots_7511_testChannels.pdf|Run 7511]] - Shows all channels good again :) | * [[media:SummaryPlots_7511_testChannels.pdf|Run 7511]] - Shows all channels good again :) | ||
+ | |||
+ | To make these plots I have used the DAQ_Checkout.conf decoding configuration (for the CH_INJ CODA config) and used the panguin macro QualityAssurance/testChannels.cfg | ||
[[Category:DAQ_Testing]] | [[Category:DAQ_Testing]] |
Latest revision as of 13:49, 4 August 2020
Back to Main Page >> DAQ Documentation Portal >> DAQ Testing >> DAQ Commissioning Notes
Previous Day of Testing << >> Next Day of Testing
July 30th, 2020 Tester: Cameron Clarke
Replacing VQWK number 032 from CH _5_2 bad channel
To make these plots I have used the DAQ_Checkout.conf decoding configuration (for the CH_INJ CODA config) and used the panguin macro QualityAssurance/testChannels.cfg