=== Production Run List - Slug 186 - IHWP OUT - Flip-RIGHT - Production/Recommissioning === | === Production Run List - Slug 186 - IHWP OUT - Flip-RIGHT - Production/Recommissioning === | ||
− | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/ | + | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7627_000 Run 7627] - Has a brief bpm12X excursion, 1mm. Otherwise good looking 120 uA run. Aq feedback was off for a portion, but it still looks good anyway - as good as later data in this slug (noisy BPMs come in later and make the rest of the slug a mess) |
− | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/ | + | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7628_000 Run 7628] - noisy beam positions due to FFB issues. One brief excursion in BPM 12X |
− | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/ | + | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7629_000 Run 7629] - Large Y BPM motion (nearly 2mm) but right on the boundary of too much. Seems OK |
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7630_000 Run 7630] - Brief moments of 12X excursion, acceptable I think. Two main BCMs disagree somewhat. | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7631_000 Run 7631] - more large BPM Y motion and some 12X small noise, but all looks good | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7632_000 Run 7632] - looks good. Same bad BPM Y noise | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7634_000 Run 7634] - looks as good as the rest of the slug | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7635_000 Run 7635] - looks as good as the rest of the slug | ||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == | ||
− | * | + | * Suspicious - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7626_000 Run 7626] - Initial production run after target burn-off, while commissioning BMOD and no Aq feedback |
+ | * Junk - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7633_000 Run 7633] - Carbon 1%, FFB work for a bit | ||
== Issues == | == Issues == | ||
Line 36: | Line 42: | ||
* Detectors are in exactly the same spots and conditions as in March | * Detectors are in exactly the same spots and conditions as in March | ||
* Pedestals need to be obtained in a few days and these runs reprompted | * Pedestals need to be obtained in a few days and these runs reprompted | ||
+ | * CREX bullseye scan is taken, with Tune Beam - https://logbooks.jlab.org/entry/3824600 | ||
[[Category:WAC]] | [[Category:WAC]] |
Latest revision as of 15:08, 9 November 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes April 22 2020 << >> WAC Notes August 12 2020
August 11 2020
Daily Meeting BlueJeans
Production Run List - Slug 186 - IHWP OUT - Flip-RIGHT - Production/Recommissioning
- Good - Run 7627 - Has a brief bpm12X excursion, 1mm. Otherwise good looking 120 uA run. Aq feedback was off for a portion, but it still looks good anyway - as good as later data in this slug (noisy BPMs come in later and make the rest of the slug a mess)
- Good - Run 7628 - noisy beam positions due to FFB issues. One brief excursion in BPM 12X
- Good - Run 7629 - Large Y BPM motion (nearly 2mm) but right on the boundary of too much. Seems OK
- Good - Run 7630 - Brief moments of 12X excursion, acceptable I think. Two main BCMs disagree somewhat.
- Good - Run 7631 - more large BPM Y motion and some 12X small noise, but all looks good
- Good - Run 7632 - looks good. Same bad BPM Y noise
- Good - Run 7634 - looks as good as the rest of the slug
- Good - Run 7635 - looks as good as the rest of the slug
Non-Production Runs and Bad Runs
- Suspicious - Run 7626 - Initial production run after target burn-off, while commissioning BMOD and no Aq feedback
- Junk - Run 7633 - Carbon 1%, FFB work for a bit
Issues
- FFB issues abound, giving unstable positions and very broad BPM Y yield and diff noise
- Initial runs have bad FFB, Aq, and BMOD, but are probably salvageable
Updates
- Detectors are in exactly the same spots and conditions as in March
- Pedestals need to be obtained in a few days and these runs reprompted
- CREX bullseye scan is taken, with Tune Beam - https://logbooks.jlab.org/entry/3824600