Difference between revisions of "WAC Notes August 25 2020"
From PREX Wiki
Jump to navigationJump to search(6 intermediate revisions by the same user not shown) | |||
Line 25: | Line 25: | ||
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7981_000 Run 7981] | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7981_000 Run 7981] | ||
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7983_000 Run 7983] -- septum trips off 3 times during this run | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7983_000 Run 7983] -- septum trips off 3 times during this run | ||
− | |||
− | |||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == | ||
− | * Junk - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7982_000 Run 7982] -- a short run (8 mins, with only ~2k good patterns) | + | * Junk - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7982_000 Run 7982] -- a short run (8 mins, with only ~2k good patterns) |
+ | * Junk - run 7984-7992: to check septum in the hall and Cryomodule problem in the machine | ||
== Issues == | == Issues == | ||
Line 35: | Line 34: | ||
== Updates == | == Updates == | ||
− | * Devi did an alignment check | + | * Q2 (Ca48) measurement: https://logbooks.jlab.org/entry/3834239 |
− | + | * Devi did an alignment check with Q2 data: https://logbooks.jlab.org/entry/3834370 | |
+ | ** both arms are accepting ~2 mm more, compared to the alignment check on 8/16/2020 (https://logbooks.jlab.org/entry/3828828) | ||
[[Category:WAC]] | [[Category:WAC]] |
Latest revision as of 19:53, 27 August 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes August 24 2020 << >> WAC Notes August 26 2020
August 25 2020
Daily Meeting BlueJeans
Production Run List - Slug 203 - IHWP IN - Flip-RIGHT - Production
Non-Production Runs and Bad Runs
- Junk - Run 7982 -- a short run (8 mins, with only ~2k good patterns)
- Junk - run 7984-7992: to check septum in the hall and Cryomodule problem in the machine
Issues
- Septum trips off a million times during the Day and Swing shifts, maybe related to the hall temperature: https://logbooks.jlab.org/entry/3834792
Updates
- Q2 (Ca48) measurement: https://logbooks.jlab.org/entry/3834239
- Devi did an alignment check with Q2 data: https://logbooks.jlab.org/entry/3834370
- both arms are accepting ~2 mm more, compared to the alignment check on 8/16/2020 (https://logbooks.jlab.org/entry/3828828)