Difference between revisions of "20180703-Optics-Mtg"
From PREX Wiki
Jump to navigationJump to search(One intermediate revision by one other user not shown) | |||
Line 14: | Line 14: | ||
== Agenda == | == Agenda == | ||
+ | Ryan: [https://prex.jlab.org/cgi-bin/DocDB/private/ShowDocument?docid=174] | ||
+ | == Minutes == | ||
+ | * Reviewed results for Seamus' new collimator | ||
+ | * Will send Tyler collimator function to test | ||
− | + | * Ryan | |
+ | ** Focus positions in VDCs have two minima | ||
+ | ** Doing FWHM to get mistune size (transverse width is sensitive to septum) | ||
+ | ** Looks like there are some AT enhancements along the lines of the data! | ||
+ | ** AT range between data and simulation is very different |
Latest revision as of 18:59, 17 July 2018
Back to Main Page >> HRS_Optics_Mtg
previous meeting << >> following meeting
Logistic information
BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 International toll number: 408-740-7256 PARTICIPANT CODE: #9989030149 Room IRL: <none>
Agenda
Ryan: [1]
Minutes
- Reviewed results for Seamus' new collimator
- Will send Tyler collimator function to test
- Ryan
- Focus positions in VDCs have two minima
- Doing FWHM to get mistune size (transverse width is sensitive to septum)
- Looks like there are some AT enhancements along the lines of the data!
- AT range between data and simulation is very different