Difference between revisions of "20180828-Optics-Mtg"
From PREX Wiki
Jump to navigationJump to search (→Agenda) |
|||
Line 19: | Line 19: | ||
== Minutes == | == Minutes == | ||
+ | * Tyler has g4hrs up to date in repository | ||
+ | ** Did return for focus at 0.9m downstream from VDS | ||
+ | ** Better agreement with Ryan's hrstrans matrices now | ||
+ | ** Central ray downstream of HRS dipole offcenter in quads - no way to recenter both position and angle | ||
+ | |||
+ | * Ryan comparing sieve data | ||
+ | ** Mistune data doesn't match HRStrans | ||
+ | ** Reconstruction matrices not redone in calibration, so target variables will be distorted | ||
+ | ** Suggest looking at reproducing data with misreconstructed simulation |
Latest revision as of 10:54, 10 September 2018
Back to Main Page >> HRS_Optics_Mtg
previous meeting << >> following meeting
Logistic information
BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 International toll number: 408-740-7256 PARTICIPANT CODE: #9989030149 Room IRL: <none>
Agenda
- Tyler Quad tune in g4hrs
- Ryan Optics Update
- Dustin Quartz thickness (if time)
Minutes
- Tyler has g4hrs up to date in repository
- Did return for focus at 0.9m downstream from VDS
- Better agreement with Ryan's hrstrans matrices now
- Central ray downstream of HRS dipole offcenter in quads - no way to recenter both position and angle
- Ryan comparing sieve data
- Mistune data doesn't match HRStrans
- Reconstruction matrices not redone in calibration, so target variables will be distorted
- Suggest looking at reproducing data with misreconstructed simulation