Difference between revisions of "WAC Notes July 25 2019"
From PREX Wiki
Jump to navigationJump to search(22 intermediate revisions by the same user not shown) | |||
Line 21: | Line 21: | ||
=== Production Run List === | === Production Run List === | ||
− | Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug13 | + | Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug13/ Slug 13, IHWP OUT Flip Right, FFB on always] |
+ | ***'''Since we are using bcm_dg_ds, the width in the bcm is ~1.5X of what we used to have with bcm_an_ds3''' | ||
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3622_000 run3622] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3622_000 run3622] | ||
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3623_000 run3623] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3623_000 run3623] | ||
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3624_000 run3624] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3624_000 run3624] | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3625_000/ run3625] |
− | ** Mini-run 0 | + | ** Mini-run 0 had too large detector widths->'''Fixed after bad_event_cut''' |
− | |||
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3626_000 run3626] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3626_000 run3626] | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3629_000 run3629] |
− | + | ** Aq mean was large for first two miniruns | |
− | ** Aq mean | + | ** bad_evt_cut applied, now good |
− | ** | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3630_000 run3630]'''ADDED from suspicious list''' |
− | * | ||
** Detector widths are fluctuating between mini-runs. | ** Detector widths are fluctuating between mini-runs. | ||
− | * | + | ** First run with detector width started increasing |
+ | ** Applied bad_evt_cut, now good | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3631_000 run3631]'''ADDED from suspicious list''' | ||
** Detector widths become worse | ** Detector widths become worse | ||
** Beam position change | ** Beam position change | ||
** Beam current fluctuating | ** Beam current fluctuating | ||
+ | ** Normalized detector yield is decreasing over time | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-26/run3632_000 run3632]'''ADDED from suspicious list''' | ||
+ | ** Regressed detector widths are even higher | ||
+ | ** Normalized detector yield is decreasing over time | ||
+ | ** Regressed detectors are correlated | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-26/run3633_000 run3633]'''ADDED from suspicious list''' | ||
+ | ** Normalized detector yield is increasing over time (opposite to run3632) | ||
+ | ** Regressed detectors are correlated | ||
+ | ** Regressed detector widths are larger | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3634_000 run3634]'''ADDED from suspicious list''' | ||
+ | ** Normalized detector yield is increasing over time (opposite to run3632) | ||
+ | ** Regressed detectors are correlated | ||
+ | ** Regressed detector widths are larger | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3635_000 run3635]'''ADDED from suspicious list''' | ||
+ | ** Normalized detector yield is increasing over time (opposite to run3632) | ||
+ | ** Regressed detectors are correlated | ||
+ | ** Regressed detector widths are larger | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3636_000 run3636]'''ADDED from suspicious list''' | ||
+ | ** Long beam trip during the run | ||
+ | ** Normalized detector yield is decreasing again | ||
+ | ** Regressed detector widths are larger | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3640_000 run3640]'''ADDED from suspicious list''' | ||
+ | ** This run was taken during collimator scan | ||
+ | ** Aq widths are too large | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3641_000 run3641]'''ADDED from suspicious list''' | ||
+ | ** Aq widths are too large (>200ppm) | ||
+ | ** Started with 1uA checking position then go to 70uA | ||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == | ||
+ | * Test - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3628_000 run3628] | ||
== Pedestal/Calibrations Updates == | == Pedestal/Calibrations Updates == |
Latest revision as of 20:46, 6 August 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions
WAC Notes July 24 2019 << >> WAC Notes July 26 2019
July 25 2019
Production Run List
Start Slug 13, IHWP OUT Flip Right, FFB on always
- Since we are using bcm_dg_ds, the width in the bcm is ~1.5X of what we used to have with bcm_an_ds3
- Good - run3622
- Good - run3623
- Good - run3624
- Good - run3625
- Mini-run 0 had too large detector widths->Fixed after bad_event_cut
- Good - run3626
- Good - run3629
- Aq mean was large for first two miniruns
- bad_evt_cut applied, now good
- Good - run3630ADDED from suspicious list
- Detector widths are fluctuating between mini-runs.
- First run with detector width started increasing
- Applied bad_evt_cut, now good
- Good - run3631ADDED from suspicious list
- Detector widths become worse
- Beam position change
- Beam current fluctuating
- Normalized detector yield is decreasing over time
- Good - run3632ADDED from suspicious list
- Regressed detector widths are even higher
- Normalized detector yield is decreasing over time
- Regressed detectors are correlated
- Good - run3633ADDED from suspicious list
- Normalized detector yield is increasing over time (opposite to run3632)
- Regressed detectors are correlated
- Regressed detector widths are larger
- Good - run3634ADDED from suspicious list
- Normalized detector yield is increasing over time (opposite to run3632)
- Regressed detectors are correlated
- Regressed detector widths are larger
- Good - run3635ADDED from suspicious list
- Normalized detector yield is increasing over time (opposite to run3632)
- Regressed detectors are correlated
- Regressed detector widths are larger
- Good - run3636ADDED from suspicious list
- Long beam trip during the run
- Normalized detector yield is decreasing again
- Regressed detector widths are larger
- Good - run3640ADDED from suspicious list
- This run was taken during collimator scan
- Aq widths are too large
- Good - run3641ADDED from suspicious list
- Aq widths are too large (>200ppm)
- Started with 1uA checking position then go to 70uA
Non-Production Runs and Bad Runs
- Test - run3628
Pedestal/Calibrations Updates
Issues
- There were many pedestal and event cut problems. From now on, when an event cut isn't absolutely necessary it should be removed - see japan source code for reference of cuts here
- The BCM appears to be falling apart. We are fixing it and running slug 12 on BCM DG DS in the meantime.
- BPM 4ec had intermittant problems (iocse10 has issues) and so we are regressing with 4e again. BPM 11X is ok and stays in regression.
- Increase in Detector widths and Collimator temperature HALOG COLLIMATOR HALOG
- Increase in collimator temperature and raising neutron dose HALOG
- The increase in detector widths started from late Swing Shift HALOG
- Cavity BPM lock change HALOG