== January 17 2020 ==
Line 21: Line 21:
 
'''Daily Meeting [https://bluejeans.com/454783784 BlueJeans]'''
 
'''Daily Meeting [https://bluejeans.com/454783784 BlueJeans]'''
  
=== Production Run List - Slug 109 - IHWP OUT - Flip-RIGHT - Production ===
+
=== Production Run List - Slug 110 - IHWP IN - Flip-RIGHT - Production ===
  
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5655_000 Run 5655] - Cut at 150k-170k to remove beam motion (caused by 120 uA running)
+
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5786_000 Run 5786] - some beam motion, but not > 0.5 mm, so leaving it in. Clear 60 Hz noise in the beam... FFB seems to be off. Some <150 uA data, but its short and OK (wider widths)
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5656_000 Run 5656]
+
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5787_000 Run 5787] - looks good. Similar not-quite-cuttable beam motion at the beginning. Some clipping in the injector for a moment
* HELP - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5749_000 Run 5749] - IHWP Slow tree read failure
+
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5788_000 Run 5788] - beam excursion at the end, and large Aq wings at the beginning. Cut out 375000-> and 10k-20k
 +
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5789_000 Run 5789] - bad Y beam motion. Cutting out 125000:140000, 160000:190000, 340000:360000
 +
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5790_000 Run 5790]
 +
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5791_000 Run 5791] - cutting out 170K onward due to large beam motion
 +
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5792_000 Run 5792] - wild beam instability up to 175K cut, otherwise good
 +
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5793_000 Run 5793] - pretty bad clipping in injector this time... cut 200-260k
 +
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5794_000 Run 5794] - beam motion towards the end in Y - cutting 270000:320000, and 340000:370000
 +
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5795_000 Run 5795] - the beam moves around a bit. Clean RMS on the main detectors :)
  
 
== Non-Production Runs and Bad Runs ==
 
== Non-Production Runs and Bad Runs ==
Line 35: Line 42:
 
== Issues ==
 
== Issues ==
  
* Run 5749 has a cut problem
+
* Cut out lots of clipping in the injector. '''It isn't necessary for our data quality, so consider undoing'''
* Compton and BMW tuning at 5750 changes things:
 
** Moves BPM 1x -3mm
 
** Asym widths get wider on Right Arm
 
** Slopes of 4eX and 12X change a lot
 
  
=== Counting Mode Downstream Detectors ===
 
* Removed from cuts and correlator channel maps for safety
 
  
 
[[Category:WAC]]
 
[[Category:WAC]]

Latest revision as of 06:09, 3 February 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes January 16 2020 << >> WAC Notes January 18 2020

January 17 2020

Daily Meeting BlueJeans

Production Run List - Slug 110 - IHWP IN - Flip-RIGHT - Production

  • Good - Run 5786 - some beam motion, but not > 0.5 mm, so leaving it in. Clear 60 Hz noise in the beam... FFB seems to be off. Some <150 uA data, but its short and OK (wider widths)
  • Good - Run 5787 - looks good. Similar not-quite-cuttable beam motion at the beginning. Some clipping in the injector for a moment
  • Good - Run 5788 - beam excursion at the end, and large Aq wings at the beginning. Cut out 375000-> and 10k-20k
  • Good - Run 5789 - bad Y beam motion. Cutting out 125000:140000, 160000:190000, 340000:360000
  • Good - Run 5790
  • Good - Run 5791 - cutting out 170K onward due to large beam motion
  • Good - Run 5792 - wild beam instability up to 175K cut, otherwise good
  • Good - Run 5793 - pretty bad clipping in injector this time... cut 200-260k
  • Good - Run 5794 - beam motion towards the end in Y - cutting 270000:320000, and 340000:370000
  • Good - Run 5795 - the beam moves around a bit. Clean RMS on the main detectors :)

Non-Production Runs and Bad Runs

Pedestal/Calibrations Updates

Issues

  • Cut out lots of clipping in the injector. It isn't necessary for our data quality, so consider undoing