=== Production Run List - Slug 119 - IHWP OUT - Flip-RIGHT - Production === | === Production Run List - Slug 119 - IHWP OUT - Flip-RIGHT - Production === | ||
− | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/ | + | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5958_000 Run 5958] - good |
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5959_000 Run 5959] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5960_000 Run 5960] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5961_000 Run 5961] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5962_000 Run 5962] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5963_000 Run 5963] - some minor beam motion. adding bpm 4ex < 0.3 event cut to remove a trip recovery issue. ALL good | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5964_000 Run 5964] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5965_000 Run 5965] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5966_000 Run 5966] | ||
+ | |||
+ | === Production Run List - Slug 120 - IHWP IN - Flip-RIGHT - Production === | ||
+ | |||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5967_000 Run 5967] - good | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5968_000 Run 5968] - a minor beam excursion in the middle of the run, but OK | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5969_000 Run 5969] - another minor beam excursion in the middle of the run, but OK | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5970_000 Run 5970] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5971_000 Run 5971] | ||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == | ||
+ | |||
+ | * Good? Too short - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5972_000 Run 5972] very small run, but good, with BMW. I think this run was too short to have all the epics variables in it, as such marking as suspicious (it should be good for BMW analysis though hopefully) | ||
== Pedestal/Calibrations Updates == | == Pedestal/Calibrations Updates == |
Latest revision as of 15:00, 28 March 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes January 26 2020 << >> WAC Notes January 29 2020
January 27 2020
Daily Meeting BlueJeans
Production Run List - Slug 119 - IHWP OUT - Flip-RIGHT - Production
- Good - Run 5958 - good
- Good - Run 5959
- Good - Run 5960
- Good - Run 5961
- Good - Run 5962
- Good - Run 5963 - some minor beam motion. adding bpm 4ex < 0.3 event cut to remove a trip recovery issue. ALL good
- Good - Run 5964
- Good - Run 5965
- Good - Run 5966
Production Run List - Slug 120 - IHWP IN - Flip-RIGHT - Production
- Good - Run 5967 - good
- Good - Run 5968 - a minor beam excursion in the middle of the run, but OK
- Good - Run 5969 - another minor beam excursion in the middle of the run, but OK
- Good - Run 5970
- Good - Run 5971
Non-Production Runs and Bad Runs
- Good? Too short - Run 5972 very small run, but good, with BMW. I think this run was too short to have all the epics variables in it, as such marking as suspicious (it should be good for BMW analysis though hopefully)
Pedestal/Calibrations Updates
- https://docs.google.com/spreadsheets/d/1mt39fCuIW3Pr8TO7fzhtFjmMFt4Op30jMm5wMQke6Xo/edit?usp=sharing
Issues
- Residual Aq correlation in HRS sometimes
- Large noise in RHRS main det (pedestal noise?)
- Low beam current
- Need calibrations again
- BCM sees noise off the Hall A laser sometimes -> how much, % of experiment data cut?