Difference between revisions of "WAC Notes February 17 2020"
From PREX Wiki
Jump to navigationJump to searchLine 36: | Line 36: | ||
** Detector width is still large | ** Detector width is still large | ||
** Large residual correlation of detector (USR) with AqUS and AqDS | ** Large residual correlation of detector (USR) with AqUS and AqDS | ||
− | |||
− | |||
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run6443_000 Run 6443] | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run6443_000 Run 6443] | ||
** Detector width is still large | ** Detector width is still large |
Revision as of 09:43, 17 February 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes February 16 2020 << >> WAC Notes February 18 2020
February 17 2020
Daily Meeting BlueJeans
Production Run List - Slug 136 - IHWP IN - Flip-RIGHT - Production
Start this slug at ~10:04am, February 16
- Good - Run 6439
- Aq slightly larger in minirun 0, detector width is also large. USR has ~11% residual correlation with AqDS
- ~10 ppm larger detector slope
- Good - Run 6440
- LQ1 tripped, applied event_cut at the end of the run
- Detector width is still large
- Good - Run 6441
- LQ1 tripped, applied event_cut at the end of the run
- Very short run
- Detector width is still large
- Large residual correlation of detector (USR) with AqUS and AqDS
- Good - Run 6443
- Detector width is still large
- Good - Run 6444
- Detector width is still large
- Good - Run 6445
- Large Aq for minirun 4
- Detector width is still large
- NeedCut - Run 6446
- Energy BPM wires saturated
- Detector width is still large
- NeedCut - Run 6447
- Energy BPMs saturated many times. FFB ON/OFF to investigate this issue
- Good - Run 6448
- Some beam excursion in the beginning of the run
- NeedCut - Run 6449
- ~ 1mm of beam excursion at the end. Quite large Aq in 0th and 2nd minirun
- NeedCut - Run 6451
- ~ 1mm beam excursion in the beginning
- NeedCut - Run 6452
- ~0.8mm of beam excursion at the end. 4ec again sees this huge. bpm12X also has ~0.8mm-1mm of excursion
- Due to the excursion detector yield has changed (increased in USR and decrease in USL). SAMMs also see this.
- Good - Run 6455
- Good - Run 6456
- Good - Run 6457
- Good - Run 6458
- Aq little bit noisy at the end part of the run
- NeedCut - Run 6459
- Some intermittent energy excursions ~1mm
Non-Production Runs and Bad Runs
Pedestal/Calibrations Updates
- https://docs.google.com/spreadsheets/d/1mt39fCuIW3Pr8TO7fzhtFjmMFt4Op30jMm5wMQke6Xo/edit?usp=sharing