Difference between revisions of "WAC Notes August 16 2020"
From PREX Wiki
Jump to navigationJump to search (Created page with "=== Production Run List - Slug 190 - IHWP OUT - Flip-RIGHT === Continued from yeterday's run here ===='''Back to the OLD Moller quads tune''' - ''...") |
m |
||
Line 1: | Line 1: | ||
+ | {| cellpadding=5 style="margin:7px 30px 0 30px; <!-- | ||
+ | --> float:right; border:1px solid #AA6633" | ||
+ | |- bgcolor="#fbfeff" | ||
+ | |- | ||
+ | |[[Documentation]] | ||
+ | |- | ||
+ | | [[HOW TOs | HOW TOs for shift crew]] | ||
+ | |- | ||
+ | | [[Expert Tools]] | ||
+ | |- | ||
+ | | [https://docs.google.com/spreadsheets/d/1XL5UY-VVrMkUwjbNzQ7xb6f4rYyqHwUpd034jckEjq0/edit?usp=sharing All Expert Contacts] | ||
+ | |} | ||
+ | |||
+ | <br> | ||
+ | [[Main_Page|<B>PREX Main</B>]] << [[Weekly Analysis Coordinator]] << [[WAC Notes CREX]] << [[WAC|Instructions]] | ||
+ | <br><br> | ||
+ | [[WAC Notes August 14 2020]] << >> [[WAC Notes August 16 2020]] | ||
+ | |||
+ | == August 15 2020 == | ||
+ | |||
+ | '''Daily Meeting [https://bluejeans.com/454783784 BlueJeans]''' | ||
+ | |||
=== Production Run List - Slug 190 - IHWP OUT - Flip-RIGHT === | === Production Run List - Slug 190 - IHWP OUT - Flip-RIGHT === | ||
Continued from yeterday's run [[WAC_Notes_August_15_2020|here]] | Continued from yeterday's run [[WAC_Notes_August_15_2020|here]] | ||
Line 13: | Line 35: | ||
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7762_000 Run 7762] - | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7762_000 Run 7762] - | ||
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7763_000 Run 7763] - | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7763_000 Run 7763] - | ||
+ | |||
+ | == Non-Production Runs and Bad Runs == | ||
+ | |||
+ | == Issues == | ||
+ | * Running with FFB off | ||
+ | * Moller quads failed and we got a different tune over night. The data seems OK anyway | ||
+ | * Run 7761 for Compton tuning on C-1%, needed vertical table move | ||
+ | |||
+ | == Updates == | ||
+ | * BMOD tune seems OK. | ||
+ | * I found another bug in code - was always using 4aX BPM even in 1X case for corrections... now fixed | ||
+ | * It appears 1X 15746 BMOD analysis is the best for the last few days of running. Needs re-analysis to pick up pedestal fix and get the full run lists all analyzed again. | ||
+ | |||
+ | [[Category:WAC]] |
Revision as of 04:31, 16 August 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes August 14 2020 << >> WAC Notes August 16 2020
August 15 2020
Daily Meeting BlueJeans
Production Run List - Slug 190 - IHWP OUT - Flip-RIGHT
Continued from yeterday's run here
Back to the OLD Moller quads tune - Septum hadn't been cycled after hall work
- Good - Run 7759 - Looks good.
- 100 uA for most of the run.
- First run back with the originally used Moller quad tune set up.
- Noticed the SBS and HES septum magnet power supplies both weren't cycled correctly around noon and cycled them now.
RHRS Dipole tripped
- Good - Run 7760 - Looks good
- Cut out :70k events for large beam motion at the beginning of the run.
- R dipole tripped -> Set RHRS main detectors to local cuts and no-blinding and no-normalization
- Good - Run 7762 -
- Good - Run 7763 -
Non-Production Runs and Bad Runs
Issues
- Running with FFB off
- Moller quads failed and we got a different tune over night. The data seems OK anyway
- Run 7761 for Compton tuning on C-1%, needed vertical table move
Updates
- BMOD tune seems OK.
- I found another bug in code - was always using 4aX BPM even in 1X case for corrections... now fixed