Difference between revisions of "WAC Notes August 16 2020"

From PREX Wiki
Jump to navigationJump to search
m
m
Line 15: Line 15:
 
[[Main_Page|<B>PREX Main</B>]] << [[Weekly Analysis Coordinator]] << [[WAC Notes CREX]] << [[WAC|Instructions]]
 
[[Main_Page|<B>PREX Main</B>]] << [[Weekly Analysis Coordinator]] << [[WAC Notes CREX]] << [[WAC|Instructions]]
 
<br><br>
 
<br><br>
[[WAC Notes August 14 2020]] << >> [[WAC Notes August 16 2020]]
+
[[WAC Notes August 15 2020]] << >> [[WAC Notes August 17 2020]]
  
== August 15 2020 ==
+
== August 16 2020 ==
  
 
'''Daily Meeting [https://bluejeans.com/454783784 BlueJeans]'''
 
'''Daily Meeting [https://bluejeans.com/454783784 BlueJeans]'''

Revision as of 06:07, 16 August 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts


PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes August 15 2020 << >> WAC Notes August 17 2020

August 16 2020

Daily Meeting BlueJeans

Production Run List - Slug 190 - IHWP OUT - Flip-RIGHT

Continued from yeterday's run here

Back to the OLD Moller quads tune - Septum hadn't been cycled after hall work

  • Good - Run 7759 - Looks good.
    • 100 uA for most of the run.
    • First run back with the originally used Moller quad tune set up.
    • Noticed the SBS and HES septum magnet power supplies both weren't cycled correctly around noon and cycled them now.

Production Run List - Slug 191 - IHWP OUT - Flip-RIGHT

RHRS Dipole tripped, its own slug

  • Good - Run 7760 - Looks good
    • Cut out :70k events for large beam motion at the beginning of the run.
    • R dipole tripped -> Set RHRS main detectors to local cuts and no-blinding and no-normalization
  • Good - Run 7762 - Looks good. 12X BPM jumps, need to cut out >1mm, < -1mm. LHRS only run, R Dipole tripped
  • Good - Run 7763 -
  • Good - Run 7764 -
  • Good - Run 7765 -
  • Good - Run 7766 -

Non-Production Runs and Bad Runs

Issues

  • Running with FFB off
  • Moller quads failed and we got a different tune over night. The data seems OK anyway
  • Run 7761 for Compton tuning on C-1%, needed vertical table move

Updates

  • BMOD tune seems OK.
  • I found another bug in code - was always using 4aX BPM even in 1X case for corrections... now fixed
  • It appears 1X 15746 BMOD analysis is the best for the last few days of running. Needs re-analysis to pick up pedestal fix and get the full run lists all analyzed again.