For shift workers
- Either the Event Builder (EB1) or Event Recorder (ER1) are disconnected (see Figure 7)
- type kcoda in a terminal, say Y(see Figure 8)
- startcoda (follow instructions for starting CODA)
- If a ROC is disconnected (see Figures 9 and 10)
- try to reset; if successful you should get Client is back message and everything should report Configured
- if a ROC is still reporting a problem - note which ROC is reporting the problem
- if the console for that ROC is responding type reboot and enter (see Figure 11)
- otherwise, use the remote power cycle to reboot that ROC (link to be added later)