Difference between revisions of "BMOD 06142019"

From PREX Wiki
Jump to navigationJump to search
Line 49: Line 49:
 
** 3 x coils, 3 y coils - which is best to do analysis (Ye)
 
** 3 x coils, 3 y coils - which is best to do analysis (Ye)
 
** coil 1 and 3 for x may be different for PREX tune
 
** coil 1 and 3 for x may be different for PREX tune
** Need a [[PREX2RunPlan2019#Establish Production Conditions | plan]]
+
** Need a [[PREX2RunPlan2019#Establish Production Conditions | plan]] - Victoria will write it and circulate it
 
* Controls - Tao
 
* Controls - Tao
 
* Aggregator - Sakib
 
* Aggregator - Sakib

Revision as of 10:29, 14 June 2019

In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.


previous meeting << >> following meeting

PREX Main << Expert Tools << Beam Modulation << Meetings

Logistic information

 BlueJeans calling instructions:
 Toll-Free Number (U.S.&  Canada):  888-240-2560
 International toll number:         408-740-7256
 Bluejeans CODE:                  348 778 076
 Bluejeans link: https://bluejeans.com/348778076
 Offline room:   CEBAF Center F324-325

Agenda


Minutes

  • Introductions
  • Overview - Victoria
    • detector response to changes in beam
    • sequentially move in set of directions (beam modulation)
    • detector yield vs. <beam position> => slopes
    • partial derivative of bpm (or detector) vs. driving coil => sensitivities
      • correlation plot or fit -> matrix, allows to calculate the slope
    • regression on natural beam motion also
  • Status - Ye and Victoria
    • coils work, know which direction
    • don't know whether positive current means a certain direction
    • modulation controls - sends current to coils, pause FFB
    • know which BPMs, and which work (tested during APEX)
      • x motion the noise of the beam seemed larger
      • probably because of energy lock not being on
      • BPM12X at a location - should have large correlation with energy
    • don't know for a given coils - position and angle of beam (at target)
    • 5 BPMS 4AX, 4EX, 12X,
    • 3 x coils, 3 y coils - which is best to do analysis (Ye)
    • coil 1 and 3 for x may be different for PREX tune
    • Need a plan - Victoria will write it and circulate it
  • Controls - Tao
  • Aggregator - Sakib
  • Documentation needed
  • meeting times

Attending: Juliette, Paul, Victoria, Ye, Tao, Sakib, Quinn, Dave Armstrong