Difference between revisions of "WAC Notes July 22 2019"
From PREX Wiki
Jump to navigationJump to search (Created page with "{| cellpadding=5 style="margin:7px 30px 0 30px; <!-- --> float:right; border:1px solid #AA6633" |- bgcolor="#fbfeff" |- |Documentation |- | HOW TOs | HOW TOs for shif...") |
|||
Line 24: | Line 24: | ||
* Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3564_000/run3564_000_all.pdf 3564]: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion | * Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3564_000/run3564_000_all.pdf 3564]: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion | ||
* Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3565_000/run3565_000_all.pdf 3565]: "" | * Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3565_000/run3565_000_all.pdf 3565]: "" | ||
− | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/ | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3566_000/run3566_000_all.pdf 3566]: Begin production on slug 11, bcm width is quite large - 200 ppm, and minirun 4 has 185 USL ppm width, which is inexplicable as far as I can tell |
− | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3567_000/run3567_000_all.pdf 3567]: large beam trip at end, BCM width got better this run | |
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3568_000/run3568_000_all.pdf 3568] | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3569_000/run3569_000_all.pdf 3569] | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3570_000/run3570_000_all.pdf 3570]: Aq ~ 0.5 ppm | ||
+ | * Blinder failed, needs cuts - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3571_000/run3571_000_all.pdf 3571]: Needs cuts to recover | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3572_000/run3572_000_all.pdf 3572] | ||
+ | * Needs cuts - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3573_000/run3573_000_all.pdf 3573]: Charge feedback went off for some events - needs cuts | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-22/run3574_000/run3574_000_all.pdf 3574]: BPM 12 slips during FFB off times | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-22/run3575_000/run3575_000_all.pdf 3575] | ||
+ | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-22/run3576_000/run3576_000_all.pdf 3576] | ||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == | ||
* Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3564_000/run3564_000_all.pdf 3564]: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion | * Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3564_000/run3564_000_all.pdf 3564]: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion | ||
* Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3565_000/run3565_000_all.pdf 3565]: "" | * Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3565_000/run3565_000_all.pdf 3565]: "" | ||
+ | * Blinder failed, needs cuts - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3571_000/run3571_000_all.pdf 3571]: Needs cuts to recover | ||
+ | * Needs cuts - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3573_000/run3573_000_all.pdf 3573]: Charge feedback went off for some events - needs cuts | ||
== Pedestal/Calibrations Updates == | == Pedestal/Calibrations Updates == | ||
+ | |||
== Issues == | == Issues == |
Revision as of 15:12, 22 July 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << Instructions
WAC Notes July 21 2019 << >> WAC Notes July 23 2019
July 22 2019
Production Run List Swing 2019/07/21 - 2019/07/22 Owl
Start Slug 11, IHWP Out, FFB on always, no RHRS on 3564, junk until 3566
- Dangerous Junk - 3564: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion
- Dangerous Junk - 3565: ""
- Good - 3566: Begin production on slug 11, bcm width is quite large - 200 ppm, and minirun 4 has 185 USL ppm width, which is inexplicable as far as I can tell
- Good - 3567: large beam trip at end, BCM width got better this run
- Good - 3568
- Good - 3569
- Good - 3570: Aq ~ 0.5 ppm
- Blinder failed, needs cuts - 3571: Needs cuts to recover
- Good - 3572
- Needs cuts - 3573: Charge feedback went off for some events - needs cuts
- Good - 3574: BPM 12 slips during FFB off times
- Good - 3575
- Good - 3576
Non-Production Runs and Bad Runs
- Dangerous Junk - 3564: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion
- Dangerous Junk - 3565: ""
- Blinder failed, needs cuts - 3571: Needs cuts to recover
- Needs cuts - 3573: Charge feedback went off for some events - needs cuts