Difference between revisions of "WAC Notes July 26 2019"

From PREX Wiki
Jump to navigationJump to search
Line 25: Line 25:
 
Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug14-Left/y_postPanPlots_slug14-Left.pdf Slug 14, IHWP In, FFB on always]  
 
Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug14-Left/y_postPanPlots_slug14-Left.pdf Slug 14, IHWP In, FFB on always]  
 
*** Since we are using bcm_dg_ds, the width in the bcm asymmetry is 1.5X of what we had with bcm_an_ds
 
*** Since we are using bcm_dg_ds, the width in the bcm asymmetry is 1.5X of what we had with bcm_an_ds
* Suspicious - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3640_000 run3640]
 
** This run was taken during collimator scan
 
** Aq widths are too large
 
* Suspicious - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3641_000 run3641]
 
** Aq widths are too large (>200ppm)
 
** Started with 1uA checking position then go to 70uA
 
** Really a test run
 
 
* Suspicious - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3649_000 run3649]
 
* Suspicious - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3649_000 run3649]
 
** Short run with many beam trips  
 
** Short run with many beam trips  

Revision as of 00:37, 27 July 2019

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions

WAC Notes July 25 2019 << >> WAC Notes July 27 2019

July 26 2019

Daily Meeting BlueJeans

Production Run List

Start Slug 14, IHWP In, FFB on always

      • Since we are using bcm_dg_ds, the width in the bcm asymmetry is 1.5X of what we had with bcm_an_ds
  • Suspicious - run3649
    • Short run with many beam trips
    • Caryn says "attempting to go to production but having some FFB issues"
  • Suspicious - run3650
    • BPM11 saturated
  • Suspicious - run3651
    • BPM11 saturated
  • Good run3652
  • Good run3653
    • Aq width is larger than normal

Non-Production Runs and Bad Runs

  • Test run3637
  • Test run3638
  • Test run3639
  • Test run3642
  • Test run3643
    • Musson injects 10uA fake signal into digital system after new chassis added
  • Test run3644
    • Target Trouble Shooting
  • Test run3647
  • Attempting to production but some Feedback issue run3648

Pedestal/Calibrations Updates

Issues

Other Status Updates