Difference between revisions of "Record of Parity Settings"

From PREX Wiki
Jump to navigationJump to search
Line 34: Line 34:
  
 
*July24 start of swing: Spin dance performed and HWien angle setting changed from -15.5deg to -13deg.
 
*July24 start of swing: Spin dance performed and HWien angle setting changed from -15.5deg to -13deg.
 +
*July 31 documenting the settings before attempted 10nm move : up through at least Run3745
 +
{| class="wikitable" border="1" style="width:50%; text-align:left;border-collapse:collapse;background: lightgreen"
 +
|+ Table 1 - List of the correct settings for Insertable Half Wave Plate (IHWP) IN and OUT / Wien Flip RIGHT and LEFT.
 +
|-
 +
! style="width:20%"|  Variable || style="width:20%"| IHWPout || style="width:20%"| IHWPout  || style="width:20%"| IHWPin  || style="width:20%"| IHWPin
 +
|-.
 +
|Flip  State
 +
|FLIP-RIGHT
 +
|FLIP-LEFT
 +
|FLIP-RIGHT
 +
|FLIP-LEFT
 +
|-
 +
|RHWP
 +
|1
 +
|1
 +
|1
 +
|1
 +
|-
 +
| VWien Angle
 +
| +88°
 +
| -89.9°
 +
| +88°
 +
| -89.9°
 +
|-
 +
| Solenoid Angle
 +
| 91.19°
 +
| 86.901°
 +
| 91.19°
 +
| 86.901°
 +
|-
 +
|HWien Angle
 +
| -13°
 +
| -13°
 +
| -13°
 +
| -13°
 +
|-
 +
|PC ON/OFF
 +
|ON
 +
|ON
 +
|ON
 +
|ON
 +
|-
 +
|V PITA
 +
|303 ± 1000 counts
 +
|303 ± 1000 counts
 +
| -970 ± 1000 counts
 +
| -970 ± 1000 counts
 +
|-
 +
|V L/4
 +
|12670
 +
|12670
 +
|12670
 +
|12670
 +
|-
 +
|V aposU
 +
|1447
 +
|1447
 +
|768
 +
|768
 +
|-
 +
|V aposV
 +
|163
 +
|163
 +
| -385
 +
| -385
 +
|-
 +
|V dposV
 +
|0
 +
|0
 +
|0
 +
|0
 +
|-
 +
|V dposU
 +
|0
 +
|0
 +
|0
 +
|0
 +
|-
 +
|HallA IA
 +
|42570
 +
|42570
 +
|26046
 +
|26046
 +
|-
 +
|HallB IA
 +
|37286
 +
|37286
 +
|29353
 +
|29353
 +
|-
 +
|HallC IA
 +
|23000 ± 2000 counts
 +
|23000 ± 2000 counts
 +
|38000 ± 2000 counts
 +
|38000 ± 2000 counts
 +
|}

Revision as of 17:55, 31 July 2019

  • Prior to July 10, solenoid angle was incorrect by 3 degrees https://logbooks.jlab.org/entry/3702542
  • July 10 evening - after Run 3143 - solenoid angle fixed by injector group (was 89deg, put at 91.2deg)
  • July 11 morning- after Run 3175- Table changed to also have solenoid =91.2 (for VWein 88deg) in addition to having solenoid =86deg (for VWein -89deg)
  • changed the AposU and AposV voltages july18th,attached picture is a history of what we had until this day in Figure 5
Figure 5 - Parity Controls window old.















  • July24 start of swing: Spin dance performed and HWien angle setting changed from -15.5deg to -13deg.
  • July 31 documenting the settings before attempted 10nm move : up through at least Run3745
Table 1 - List of the correct settings for Insertable Half Wave Plate (IHWP) IN and OUT / Wien Flip RIGHT and LEFT.
Variable IHWPout IHWPout IHWPin IHWPin
Flip State FLIP-RIGHT FLIP-LEFT FLIP-RIGHT FLIP-LEFT
RHWP 1 1 1 1
VWien Angle +88° -89.9° +88° -89.9°
Solenoid Angle 91.19° 86.901° 91.19° 86.901°
HWien Angle -13° -13° -13° -13°
PC ON/OFF ON ON ON ON
V PITA 303 ± 1000 counts 303 ± 1000 counts -970 ± 1000 counts -970 ± 1000 counts
V L/4 12670 12670 12670 12670
V aposU 1447 1447 768 768
V aposV 163 163 -385 -385
V dposV 0 0 0 0
V dposU 0 0 0 0
HallA IA 42570 42570 26046 26046
HallB IA 37286 37286 29353 29353
HallC IA 23000 ± 2000 counts 23000 ± 2000 counts 38000 ± 2000 counts 38000 ± 2000 counts