Difference between revisions of "Record of Parity Settings"
From PREX Wiki
Jump to navigationJump to searchLine 34: | Line 34: | ||
*July24 start of swing: Spin dance performed and HWien angle setting changed from -15.5deg to -13deg. | *July24 start of swing: Spin dance performed and HWien angle setting changed from -15.5deg to -13deg. | ||
− | *July 31 documenting the settings before attempted 10nm move : up through | + | *July 31 documenting the settings before attempted 10nm move : up through slug23. |
{| class="wikitable" border="1" style="width:50%; text-align:left;border-collapse:collapse;background: lightgreen" | {| class="wikitable" border="1" style="width:50%; text-align:left;border-collapse:collapse;background: lightgreen" | ||
|+ Table 1 - List of the correct settings for Insertable Half Wave Plate (IHWP) IN and OUT / Wien Flip RIGHT and LEFT. | |+ Table 1 - List of the correct settings for Insertable Half Wave Plate (IHWP) IN and OUT / Wien Flip RIGHT and LEFT. | ||
Line 123: | Line 123: | ||
|29353 | |29353 | ||
|29353 | |29353 | ||
− | |- | + | |-palatchi |
|HallC IA | |HallC IA | ||
|23000 ± 2000 counts | |23000 ± 2000 counts | ||
Line 130: | Line 130: | ||
|38000 ± 2000 counts | |38000 ± 2000 counts | ||
|} | |} | ||
+ | *Aug 1, slug 24 and 25. After 1 run in slug 24, changed AposV to try to cancel position differences. https://logbooks.jlab.org/entry/3713312. IHWPin: AposV=-385 --> want delta -20nm = +400counts --> new AposV =15. IHWPout: AposV=163 --> want delta +20nm = -400counts --> new AposV =-237 |
Revision as of 19:55, 1 August 2019
- Prior to July 10, solenoid angle was incorrect by 3 degrees https://logbooks.jlab.org/entry/3702542
- July 10 evening - after Run 3143 - solenoid angle fixed by injector group (was 89deg, put at 91.2deg)
- July 11 morning- after Run 3175- Table changed to also have solenoid =91.2 (for VWein 88deg) in addition to having solenoid =86deg (for VWein -89deg)
- changed the AposU and AposV voltages july18th,attached picture is a history of what we had until this day in Figure 5
- July24 start of swing: Spin dance performed and HWien angle setting changed from -15.5deg to -13deg.
- July 31 documenting the settings before attempted 10nm move : up through slug23.
Variable | IHWPout | IHWPout | IHWPin | IHWPin |
---|---|---|---|---|
Flip State | FLIP-RIGHT | FLIP-LEFT | FLIP-RIGHT | FLIP-LEFT |
RHWP | 1 | 1 | 1 | 1 |
VWien Angle | +88° | -89.9° | +88° | -89.9° |
Solenoid Angle | 91.19° | 86.901° | 91.19° | 86.901° |
HWien Angle | -13° | -13° | -13° | -13° |
PC ON/OFF | ON | ON | ON | ON |
V PITA | 303 ± 1000 counts | 303 ± 1000 counts | -970 ± 1000 counts | -970 ± 1000 counts |
V L/4 | 12670 | 12670 | 12670 | 12670 |
V aposU | 1447 | 1447 | 768 | 768 |
V aposV | 163 | 163 | -385 | -385 |
V dposV | 0 | 0 | 0 | 0 |
V dposU | 0 | 0 | 0 | 0 |
HallA IA | 42570 | 42570 | 26046 | 26046 |
HallB IA | 37286 | 37286 | 29353 | 29353 |
HallC IA | 23000 ± 2000 counts | 23000 ± 2000 counts | 38000 ± 2000 counts | 38000 ± 2000 counts |
- Aug 1, slug 24 and 25. After 1 run in slug 24, changed AposV to try to cancel position differences. https://logbooks.jlab.org/entry/3713312. IHWPin: AposV=-385 --> want delta -20nm = +400counts --> new AposV =15. IHWPout: AposV=163 --> want delta +20nm = -400counts --> new AposV =-237