Difference between revisions of "Record of Parity Settings"
From PREX Wiki
Jump to navigationJump to searchLine 4: | Line 4: | ||
*changed the AposU and AposV voltages july18th,attached picture is a history of what we had until this day in Figure 5 | *changed the AposU and AposV voltages july18th,attached picture is a history of what we had until this day in Figure 5 | ||
[[File:Parity_settings_untill_July_18th_2019.png|thumb|600px|left|Figure 5 - Parity Controls window old.]] | [[File:Parity_settings_untill_July_18th_2019.png|thumb|600px|left|Figure 5 - Parity Controls window old.]] | ||
+ | |||
Line 131: | Line 132: | ||
|} | |} | ||
*Aug 1, slug 24 and 25. After 1 run in slug 24, changed AposV to try to cancel position differences. https://logbooks.jlab.org/entry/3713312. IHWPin: AposV=-385 --> want delta -20nm = +400counts --> new AposV =15. IHWPout: AposV=163 --> want delta +20nm = -400counts --> new AposV =-237 | *Aug 1, slug 24 and 25. After 1 run in slug 24, changed AposV to try to cancel position differences. https://logbooks.jlab.org/entry/3713312. IHWPin: AposV=-385 --> want delta -20nm = +400counts --> new AposV =15. IHWPout: AposV=163 --> want delta +20nm = -400counts --> new AposV =-237 | ||
+ | *For slugs 26 -65 used above nominal AposU/V settings: IHWPin: AposU/V=768/-385,AposU/V=1147/163 | ||
+ | *Aug 25, starting with slug66, implemented the following change: | ||
+ | IHWPin: AposU/V=768/-385 ---> new AposU/V=685/-678 (change AposU by -83 counts, change AposV by -293counts) | ||
+ | IHWPout: AposU/V=1147/163 ---> new AposU/V=1176/465 (change AposU by +29 counts, change AposV by +302counts) |
Revision as of 15:00, 25 August 2019
- Prior to July 10, solenoid angle was incorrect by 3 degrees https://logbooks.jlab.org/entry/3702542
- July 10 evening - after Run 3143 - solenoid angle fixed by injector group (was 89deg, put at 91.2deg)
- July 11 morning- after Run 3175- Table changed to also have solenoid =91.2 (for VWein 88deg) in addition to having solenoid =86deg (for VWein -89deg)
- changed the AposU and AposV voltages july18th,attached picture is a history of what we had until this day in Figure 5
- July24 start of swing: Spin dance performed and HWien angle setting changed from -15.5deg to -13deg.
- July 31 documenting the settings before attempted 10nm move : up through slug23.
Variable | IHWPout | IHWPout | IHWPin | IHWPin |
---|---|---|---|---|
Flip State | FLIP-RIGHT | FLIP-LEFT | FLIP-RIGHT | FLIP-LEFT |
RHWP | 1 | 1 | 1 | 1 |
VWien Angle | +88° | -89.9° | +88° | -89.9° |
Solenoid Angle | 91.19° | 86.901° | 91.19° | 86.901° |
HWien Angle | -13° | -13° | -13° | -13° |
PC ON/OFF | ON | ON | ON | ON |
V PITA | 303 ± 1000 counts | 303 ± 1000 counts | -970 ± 1000 counts | -970 ± 1000 counts |
V L/4 | 12670 | 12670 | 12670 | 12670 |
V aposU | 1447 | 1447 | 768 | 768 |
V aposV | 163 | 163 | -385 | -385 |
V dposV | 0 | 0 | 0 | 0 |
V dposU | 0 | 0 | 0 | 0 |
HallA IA | 42570 | 42570 | 26046 | 26046 |
HallB IA | 37286 | 37286 | 29353 | 29353 |
HallC IA | 23000 ± 2000 counts | 23000 ± 2000 counts | 38000 ± 2000 counts | 38000 ± 2000 counts |
- Aug 1, slug 24 and 25. After 1 run in slug 24, changed AposV to try to cancel position differences. https://logbooks.jlab.org/entry/3713312. IHWPin: AposV=-385 --> want delta -20nm = +400counts --> new AposV =15. IHWPout: AposV=163 --> want delta +20nm = -400counts --> new AposV =-237
- For slugs 26 -65 used above nominal AposU/V settings: IHWPin: AposU/V=768/-385,AposU/V=1147/163
- Aug 25, starting with slug66, implemented the following change:
IHWPin: AposU/V=768/-385 ---> new AposU/V=685/-678 (change AposU by -83 counts, change AposV by -293counts) IHWPout: AposU/V=1147/163 ---> new AposU/V=1176/465 (change AposU by +29 counts, change AposV by +302counts)