Difference between revisions of "Beam Modulation"

From PREX Wiki
Jump to navigationJump to search
Line 56: Line 56:
 
Each output txt file each row has runnumber      cyclenumber          flagvalue      .......................  
 
Each output txt file each row has runnumber      cyclenumber          flagvalue      .......................  
 
we need to change the flag value based on the above plot (0----outlier point; 1----good point)
 
we need to change the flag value based on the above plot (0----outlier point; 1----good point)
 +
#After we finish this for the whole slug, then <code> cd ~/PREX/prompt/beam-mod/scripts </code>
 +
 
   
 
   
 
*<span style ="color:red"> To check the singularity for dithering 5 by 5 inverse matrix   
 
*<span style ="color:red"> To check the singularity for dithering 5 by 5 inverse matrix   

Revision as of 12:08, 26 August 2019

In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.

PREX Main << Expert Tools

How to Run Beam Modulation

  • First, make sure Coda is running
  • You need to be logged in apar account on adqa3:
    •  ssh apar@adaq3 
  • Go to directory:
    •  cd /adaqfs/home/apar/vowen/BMWClient/PyGreenMonster/ 
  • Run beam modulation code:
    •  python3 ProductionModulation_Pause10Min.py 
    1. Beam modulation will automatically run for 7 days
    2. In order to quit beam modulation
      •  control+c 
        to crash out of the beam modulation program.
      •  python3 gm_bmw_clearall.py 
        to clean up the DAQ records and release the EPICS FFB pause states.

Modulation online plots

modulation coil plot Task for the analysis shift expert:

For each run, 
  • Check the online plot ( the top plot on the BMW plot page), we should see all 7 coils (colorful bars) at least for one super cycle (one bunch). If not, check the beam trips, if this run has a lot of beam trips, then check the other more stable runs. If you still miss one or more coils, then please call Ye: 803-553-3570.
  • Check the online plot ( on the BMW Cycle page ).

Dithering slopes extraction

  • To get dithering slope root file for each slug for pass1
  1. Login to the apar account on aonl2: ssh apar@aonl2
  2. cd ~/PREX/prompt/beam-mod/scripts
  3. If you haven't done a "gojapan" yet then source setup_japan.tcsh
  • To analyze for a slug, choose the corresponding list in ~/PREX/prompt/collector/run_list/
  1. Next, run ./dit_runlist_alldet.sh ~/PREX/prompt/collector/run_list/slugnumber.list
  2. The output root files are saved in the directory: ~/PREX/prompt/beam-mod/rootfiles_alldet_pass1
  3. If you want to look at the dithering slopes versus super cycle plot for each slug
    • cd ~/PREX/prompt/beam-mod/rootfiles_alldet_pass1
    • root -l 'dithering_plot_cyc.C(slugNo)'

modulation coil plot

  • To analyze for a run, choose the corresponding run number
  1. Next, run ./auto-dit_alldet.sh runNo
  2. The output root files are saved in the directory: ~/PREX/prompt/beam-mod/rootfiles_alldet_pass1
  3. If you want to look at the dithering slopes versus super cycle plot for each slug
    • cd ~/PREX/prompt/beam-mod/rootfiles_alldet_pass1
    • root -l 'dithering_plot_cyc.C(slugNo)' (will fill the "dit" tree with super cycle dithering slopes for the run into the corresponding slug )
  • To get dithering slope root file for each slug for pass2

The above dithering slope plot shows that here are couple outlier points, which need to be marked as flag=0 in the sensitivity text file. And we need to generate new slope root files with the proper flag that can be saved in the directory ~/PREX/prompt/beam-mod/rootfiles_alldet_pass2.

  1. cd ~/PREX/prompt/beam-mod/scripts/dit_11X12X_txt

modulation coil plot Each output txt file each row has runnumber cyclenumber flagvalue ....................... we need to change the flag value based on the above plot (0----outlier point; 1----good point)

  1. After we finish this for the whole slug, then cd ~/PREX/prompt/beam-mod/scripts


  • To check the singularity for dithering 5 by 5 inverse matrix
  1. cd ~/PREX/prompt/beam-mod/scripts/dit_11X12X_txt
  2. ./add_runlist_txt.sh ~/PREX/prompt/collector/run_list/slugnumber.list (generate Quartz/AT/BPMs_sensitivity_slugnumber.txt)
  3. cd ~/PREX/prompt/beam-mod/scripts/dit_11X12X_txt
  4. root -l 'sensitivity_plot_BPMs_uptodate.C(slugNo)' (plots for a whole slug)
  5. root -l 'sensitivity_plot_BPMs_uptodate.C(runNo)' (plots for a run to check the singularity after the beam tuning)
    • Check the top two plots of the last three canvas (c43, c44, c45), if the absolute Y mean is smaller than 0.1. We need to retune the beam to get proper dithering slopes.
  • To do the dithering correction
  1. The pass2 root files should be used.
  2. Get the root files cd ~/PREX/prompt/beam-mod/rootfiles_alldet_pass2(mark the out layer points as flag=0)