Line 25: | Line 25: | ||
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5655_000 Run 5655] - Cut at 150k-170k to remove beam motion (caused by 120 uA running) | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5655_000 Run 5655] - Cut at 150k-170k to remove beam motion (caused by 120 uA running) | ||
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5656_000 Run 5656] | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5656_000 Run 5656] | ||
+ | * HELP - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5749_000 Run 5749] - IHWP Slow tree read failure | ||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == |
Revision as of 13:19, 16 January 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes January 11 2020 << >> WAC Notes January 17 2020
January 16 2020
Daily Meeting BlueJeans
Production Run List - Slug 109 - IHWP OUT - Flip-RIGHT - Production
- Good - Run 5655 - Cut at 150k-170k to remove beam motion (caused by 120 uA running)
- Good - Run 5656
- HELP - Run 5749 - IHWP Slow tree read failure
Non-Production Runs and Bad Runs
Pedestal/Calibrations Updates
- https://docs.google.com/spreadsheets/d/1mt39fCuIW3Pr8TO7fzhtFjmMFt4Op30jMm5wMQke6Xo/edit?usp=sharing
Issues
- Run 5749 has a cut problem
- Compton and BMW tuning at 5750 changes things:
- Moves BPM 1x -3mm
- Asym widths get wider on Right Arm
- Slopes of 4eX and 12X change a lot
Counting Mode Downstream Detectors
- Removed from cuts and correlator channel maps for safety