Difference between revisions of "WAC Notes January 17 2020"
From PREX Wiki
Jump to navigationJump to searchm |
m |
||
Line 23: | Line 23: | ||
=== Production Run List - Slug 110 - IHWP IN - Flip-RIGHT - Production === | === Production Run List - Slug 110 - IHWP IN - Flip-RIGHT - Production === | ||
− | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5786_000 Run 5786] - | + | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5786_000 Run 5786] - some beam motion, but not > 0.5 mm, so leaving it in. Clear 60 Hz noise in the beam... FFB seems to be off. Some <150 uA data, but its short and OK (wider widths) |
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5787_000 Run 5787] - looks good. Similar not-quite-cuttable beam motion at the beginning. Some clipping in the injector for a moment | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5788_000 Run 5788] - beam excursion at the end, and large Aq wings at the beginning. Cut out 375000-> and 10k-20k | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5789_000 Run 5789] - bad Y beam motion. Cutting out 125000:140000, 160000:190000, 340000:360000 | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5790_000 Run 5790] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5791_000 Run 5791] - cutting out 170K onward due to large beam motion | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5792_000 Run 5792] - wild beam instability up to 175K cut, otherwise good | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5793_000 Run 5793] - pretty bad clipping in injector this time... cut 200-260k | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5794_000 Run 5794] - beam motion towards the end in Y - cutting 270000:320000, and 340000:370000 | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5795_000 Run 5795] - the beam moves around a bit. Clean RMS on the main detectors :) | ||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == | ||
Line 33: | Line 42: | ||
== Issues == | == Issues == | ||
+ | * Cut out lots of clipping in the injector. '''It isn't necessary for our data quality, so consider undoing''' | ||
[[Category:WAC]] | [[Category:WAC]] |
Revision as of 05:53, 3 February 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes January 16 2020 << >> WAC Notes January 26 2020
January 17 2020
Daily Meeting BlueJeans
Production Run List - Slug 110 - IHWP IN - Flip-RIGHT - Production
- Good - Run 5786 - some beam motion, but not > 0.5 mm, so leaving it in. Clear 60 Hz noise in the beam... FFB seems to be off. Some <150 uA data, but its short and OK (wider widths)
- Good - Run 5787 - looks good. Similar not-quite-cuttable beam motion at the beginning. Some clipping in the injector for a moment
- Good - Run 5788 - beam excursion at the end, and large Aq wings at the beginning. Cut out 375000-> and 10k-20k
- Good - Run 5789 - bad Y beam motion. Cutting out 125000:140000, 160000:190000, 340000:360000
- Good - Run 5790
- Good - Run 5791 - cutting out 170K onward due to large beam motion
- Good - Run 5792 - wild beam instability up to 175K cut, otherwise good
- Good - Run 5793 - pretty bad clipping in injector this time... cut 200-260k
- Good - Run 5794 - beam motion towards the end in Y - cutting 270000:320000, and 340000:370000
- Good - Run 5795 - the beam moves around a bit. Clean RMS on the main detectors :)
Non-Production Runs and Bad Runs
Pedestal/Calibrations Updates
- https://docs.google.com/spreadsheets/d/1mt39fCuIW3Pr8TO7fzhtFjmMFt4Op30jMm5wMQke6Xo/edit?usp=sharing
Issues
- Cut out lots of clipping in the injector. It isn't necessary for our data quality, so consider undoing