Difference between revisions of "WAC Notes January 26 2020"

From PREX Wiki
Jump to navigationJump to search
 
Line 22: Line 22:
  
 
=== Production Run List - Slug 118 - IHWP IN - Flip-RIGHT - Production ===
 
=== Production Run List - Slug 118 - IHWP IN - Flip-RIGHT - Production ===
 
+
* NeedCut/Decision - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5941_000 Run 5941] - Short run
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5942_000 Run 5942] - looks mostly OK, but the BCM has lots of outliers and ~1.2 ppm mean, so it should be reinvestigated later
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5942_000 Run 5942] - looks mostly OK, but the BCM has lots of outliers and ~1.2 ppm mean, so it should be reinvestigated later
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5943_000 Run 5943]
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5943_000 Run 5943]
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5944_000 Run 5944]  
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5944_000 Run 5944]  
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5950_000 Run 5950] - cut out 165000: for LQ1 trip
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5950_000 Run 5950] - cut out 165000: for LQ1 trip
 +
* Suspicious - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5951_000 Run 5951] - One Arm
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5952_000 Run 5952] - Back to full production
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5952_000 Run 5952] - Back to full production
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5953_000 Run 5953]  
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run5953_000 Run 5953]  

Latest revision as of 11:43, 31 March 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes January 25 2020 << >> WAC Notes January 27 2020

January 26 2020

Daily Meeting BlueJeans

Production Run List - Slug 118 - IHWP IN - Flip-RIGHT - Production

  • NeedCut/Decision - Run 5941 - Short run
  • Good - Run 5942 - looks mostly OK, but the BCM has lots of outliers and ~1.2 ppm mean, so it should be reinvestigated later
  • Good - Run 5943
  • Good - Run 5944
  • Good - Run 5950 - cut out 165000: for LQ1 trip
  • Suspicious - Run 5951 - One Arm
  • Good - Run 5952 - Back to full production
  • Good - Run 5953
  • Good - Run 5954
  • Good - Run 5955
  • Good - Run 5956 - beam drifts at the beginning. Looks OK
  • Good - Run 5957 - 9% residual Aq correlation, but its in the noise I guess

Non-Production Runs and Bad Runs

Lots of junk runs over the last few slugs, due to lots of tuning by Ops to be confident sending beam

  • Ca40 - Run 5948 - Ca40, slow current ramp, not much good data
  • Ca40 - Run 5949 - Ca40, slow current ramp, not much good data
  • Good, but very short and 1 Arm - Run 5950 - cut out ALL for LQ1 trip

Pedestal/Calibrations Updates

Issues

  • Everything:
    • BCMs read crazy stuff for Hall A laser/electronics (not other hall's beams): https://logbooks.jlab.org/entry/3770663
    • Ion chambers are a whole ordeal now
    • Ops can barely deliver 150 uA + other halls

Updates