+ | #Sakib: PREX slug 0-2 reviews | ||
+ | #* Charge feedback issue: Aq feedback is not running during run 3136 and 3137. Run 3140 is fine for Aq feedback | ||
+ | #* ArmFlag: runs with mis-labeled armflag, eg run 3140. KP: did you check haplog for spectrometer? SR: Yes. | ||
+ | #* CP: July 14 run 3327-3328, clipping in injector. Central values should be OK though double peaking | ||
+ | #* RM: what is your criteria for Aq feedback not running? SR: EPICS RTPPTIACNT strip chart. | ||
+ | # Tao Ye: Beam Mod. Amplitude and burp cut [http://ace.phys.virginia.edu/HAPPEX/4110 HAPLOG 4110] | ||
+ | #* KP: we should really review burp cut on production data, e.g. from Pair/mul plots | ||
+ | #* PK: one thing we can do is pattern counting failed by burp cuts from respin1 | ||
+ | #* KP: expect to have a burp cut study next meeting. | ||
=== Analysis projects === | === Analysis projects === | ||
Line 25: | Line 34: | ||
== Present == | == Present == | ||
− | + | Kent P, Amali P, Adam Z, Cameron C, Caryn P, Ciprian G, Chandan G, David A, Dustin M, Jim N, Juan Carlos C,Paul K, Robert M, Robert R, Ryan R, Siyu J, Devi A, Sakib R, Silvilu C, Victoria O, Weibin Z, Ye T, Tao Y, Ezekiel W, Hanjie L, Paul S, Krishna K, Guido U, Iris H. | |
===Excused=== | ===Excused=== | ||
Revision as of 16:15, 27 May 2020
Back to Main Page >> PREX2_Analysis
previous meeting << >> following meeting
Logistic information
Meeting room at JLab: REMOTE ONLY
BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 International toll number: 408-740-7256 Bluejeans CODE: 206 308 0414 Bluejeans link: https://bluejeans.com/2063080414
Agenda
- Sakib: PREX slug 0-2 reviews
- Charge feedback issue: Aq feedback is not running during run 3136 and 3137. Run 3140 is fine for Aq feedback
- ArmFlag: runs with mis-labeled armflag, eg run 3140. KP: did you check haplog for spectrometer? SR: Yes.
- CP: July 14 run 3327-3328, clipping in injector. Central values should be OK though double peaking
- RM: what is your criteria for Aq feedback not running? SR: EPICS RTPPTIACNT strip chart.
- Tao Ye: Beam Mod. Amplitude and burp cut HAPLOG 4110
- KP: we should really review burp cut on production data, e.g. from Pair/mul plots
- PK: one thing we can do is pattern counting failed by burp cuts from respin1
- KP: expect to have a burp cut study next meeting.
Analysis projects
- BCM double difference study
- BPM resolution
- Pedestal / Normalization BCM history
- Events/ Patterns Counter
- Dithering sensitivity/Quality re-check
- Grand statistics re-check
- Linearity check
Present
Kent P, Amali P, Adam Z, Cameron C, Caryn P, Ciprian G, Chandan G, David A, Dustin M, Jim N, Juan Carlos C,Paul K, Robert M, Robert R, Ryan R, Siyu J, Devi A, Sakib R, Silvilu C, Victoria O, Weibin Z, Ye T, Tao Y, Ezekiel W, Hanjie L, Paul S, Krishna K, Guido U, Iris H.