Difference between revisions of "WAC Notes August 18 2020"

From PREX Wiki
Jump to navigationJump to search
 
Line 39: Line 39:
  
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7835_000 Run 7835] - Energy lock wasn't engaged but seems good.
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7835_000 Run 7835] - Energy lock wasn't engaged but seems good.
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7836_000 Run 7836] - Needed to cut trailing events after 260 K.  
+
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7836_000 Run 7836] - Needed to cut trailing events after 260 K. This run contains two distinct bpm12X response regions.  
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7837_000 Run 7837] - Cut out events bpm12X<-0.5 and >1.0
+
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7837_000 Run 7837] - Cut out events bpm12X<-0.5 and >1.0.
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7838_000 Run 7838] - Cut out events bpm12X<-0.5 and >1.0. Also cutting out between 200K and 250 K to cut out a period with excessive beam motion.  
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7838_000 Run 7838] - Cut out events bpm12X<-0.5 and >1.0. Also cutting out between 200K and 250 K to cut out a period with excessive beam motion.  
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7839_000 Run 7839] -  
+
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7839_000 Run 7839] - Cut out events bpm12X<-0.5 and >1.0.
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7840_000 Run 7840] - Short run. Keeping for now.
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run7840_000 Run 7840] - Short run. Keeping for now.
  

Latest revision as of 23:06, 20 August 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts


PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes August 17 2020 << >> WAC Notes August 19 2020

August 18 2020

Daily Meeting BlueJeans

Production Run List - Slug 194 - IHWP OUT - Flip-RIGHT

  • Good - Run 7807 - Looks good. Global cut ATs for this run, as there is a clear spike in ATL1. Cut out > 0.0 and < -1.5 mm BPM 12X
  • Good - Run 7808 - Looks good. Cut out > 0.0 and < -1.5 mm BPM 12X
  • Good - Run 7809 - looks good. Coming back from a downtime
  • Good - Run 7810 - Looks good. Add BPM 12X cut out > 0.5 mm, < -1.0
  • Good - Run 7811 - looks good. Cut out BPM 12X < -1.0, > 0.5
  • Good - Run 7812 - Needed to cut BPM 12X < -1.0, > 0.5
  • Good - Run 7813 - Needed to cut BPM 12X < -1.0, > 0.5
  • Good - Run 7814 - Needed to cut BPM 12X < -1.0, > 0.5
  • Good - Run 7815 - Looks Good
  • Good - Run 7816 - Needed to cut BPM 12X < -1.0, > 0.5
  • Good - Run 7817 - Looks Good


Production Run List - Slug 195 - IHWP IN - Flip-RIGHT

  • Good - Run 7835 - Energy lock wasn't engaged but seems good.
  • Good - Run 7836 - Needed to cut trailing events after 260 K. This run contains two distinct bpm12X response regions.
  • Good - Run 7837 - Cut out events bpm12X<-0.5 and >1.0.
  • Good - Run 7838 - Cut out events bpm12X<-0.5 and >1.0. Also cutting out between 200K and 250 K to cut out a period with excessive beam motion.
  • Good - Run 7839 - Cut out events bpm12X<-0.5 and >1.0.
  • Good - Run 7840 - Short run. Keeping for now.

Non-Production Runs and Bad Runs

Issues

Updates

  • BMOD tune seems OK.