Difference between revisions of "20170427-Septum-Mtg"
From PREX Wiki
Jump to navigationJump to searchKent Paschke (talk | contribs) (→Agenda) |
Kent Paschke (talk | contribs) (→Agenda) |
||
Line 19: | Line 19: | ||
#*Q1 files have been opened but not yet meshed. | #*Q1 files have been opened but not yet meshed. | ||
# Plan for Iris: | # Plan for Iris: | ||
+ | #* check that "residual" is much less than 1, and that the "convergence factors" are 1e-3 or smaller. Guido points out this is important to be sure that Tosca has converged correctly. | ||
+ | #* Also, Iris will check the approximate number of mesh points used in the septum model. | ||
#* show field strength at iron beampipe outer surface over the range of z along the septum. | #* show field strength at iron beampipe outer surface over the range of z along the septum. | ||
#* show Bx and By as a function of z-coordinate, offset from the beam center by 1cm in the horizontal (for By) or the vertical (for Bx). | #* show Bx and By as a function of z-coordinate, offset from the beam center by 1cm in the horizontal (for By) or the vertical (for Bx). |
Latest revision as of 14:01, 26 April 2017
Back to Main Page >> Septum_Model_Mtg
previous meeting << >> following meeting
Logistic information
BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 International toll number: 408-740-7256 PARTICIPANT CODE: #733110660 Room IRL: <none>
Agenda
- Guido: Tosca calculation is better but not yet meshed finely enough for accurate results.
- Iris:
- Tosca results do show saturation, but do not correctly match onset of saturation with pre-g2p measurements. haplog:3385
- Q1 files have been opened but not yet meshed.
- Plan for Iris:
- check that "residual" is much less than 1, and that the "convergence factors" are 1e-3 or smaller. Guido points out this is important to be sure that Tosca has converged correctly.
- Also, Iris will check the approximate number of mesh points used in the septum model.
- show field strength at iron beampipe outer surface over the range of z along the septum.
- show Bx and By as a function of z-coordinate, offset from the beam center by 1cm in the horizontal (for By) or the vertical (for Bx).
- Find Bx and By in planes of x vs y, at z coordinates {20, 40, 60, 80, 100cm} downstream of the septum yoke. (perhaps use +/-1m for each coordinate.)
- open and try to mesh Q1 model
- probably not until next week: create combined model of Q1 + septum.
- ask Juliette if she knows location of Q1 relative to septum
- Plan for Kent:
- make summary of septum (g2p experience, expected currents, etc) for Friday
- Try to get information on Q1 locations, currents.
Attendance
Iris H., Kent P., Guido U.
Excused:
Juliette M