Difference between revisions of "RunPlanDaily"

From PREX Wiki
Jump to navigationJump to search
Line 134: Line 134:
 
| Swing
 
| Swing
 
|
 
|
 +
* Target pumpdown
 
|
 
|
 
|-
 
|-
Line 139: Line 140:
 
| Owl
 
| Owl
 
|
 
|
 +
* Target pumpdown
 
|
 
|
 
|-
 
|-
Line 144: Line 146:
 
| Day
 
| Day
 
|  
 
|  
* Commission lead target, 50 uA (Bob)
+
* Target cooldown
* Lumis and oversampling tests (KK, Luis, Paul)
 
 
|
 
|
 
|-
 
|-
Line 151: Line 152:
 
| Swing
 
| Swing
 
|
 
|
* Lead target, Lumis, oversampling (cont.)
+
* Tune high current beam into Hall A
 
|
 
|
 
|-
 
|-
Line 157: Line 158:
 
| Owl
 
| Owl
 
|
 
|
* Parity Quality commissioning (Kent, Rupesh, Luis, Dustin)
+
* Commission lead target, 50 uA (Bob)
* Beam monitor calibrations (Diancheng Wang, Xiaoyan Deng)  
+
* Lumis and oversampling tests (KK, Luis, Paul)
 
|
 
|
 
|-
 
|-
Line 164: Line 165:
 
| Day
 
| Day
 
|  
 
|  
* High Luminosity Detector Commissioning
+
* Access to fix left dipole
 
|
 
|
 
|-
 
|-
Line 170: Line 171:
 
| Swing
 
| Swing
 
|
 
|
* Establish Q2 measurement sequence (Dustin, Nilanga)
+
* Parity Quality commissioning (Kent, Rupesh, Luis, Dustin)
* ARC energy measurement  (Arun Saha)
+
* Beam monitor calibrations (Diancheng Wang, Xiaoyan Deng)
 
|
 
|
 
|-
 
|-
Line 177: Line 178:
 
| Owl
 
| Owl
 
|
 
|
*Moller Checkout
+
* High Luminosity Detector Commissioning
 
|
 
|
 
|-
 
|-
Line 189: Line 190:
 
| Swing
 
| Swing
 
|
 
|
 +
*Moller Checkout
 
|
 
|
 
|-
 
|-
Line 194: Line 196:
 
| Owl
 
| Owl
 
|
 
|
 +
* Establish Q2 measurement sequence (Dustin, Nilanga)
 +
* ARC energy measurement  (Arun Saha)
 
|
 
|
 
|-
 
|-
Line 215: Line 219:
 
|  
 
|  
 
|
 
|
 
+
|-
 +
| 3/28
 +
| Swing
 +
|
 +
|
 +
|-
 +
| 3/29
 +
| Owl
 +
|
 +
|
 +
|-
 +
| 3/29
 +
| Day
 +
|
 +
|
 +
|-
 +
| 3/29
 +
| Swing
 +
|
 +
|
 +
|-
 +
| 3/30
 +
| Owl
 +
|
 +
|
 +
|-
 +
| 3/30
 +
| Day
 +
|
 +
|
  
  
 
|}
 
|}

Revision as of 19:24, 24 March 2010

Daily Run Plan

Here are details of the daily run plan. See also the global Run Plan. The person responsible should ensure that a crew of experts is available for the shift. This schedule will be updated frequently by the Run Coordinator as the situation on the ground changes.


Daily Run Plan for PREX   (latest at bottom)
Date (2010) Shift ---------- Activity (Responsible) ---------- --- Status ---
03/19 Day pump down; Møller, Compton, septum install; Q2 repair

Insert sieve. (Techs)

03/19 Swing Beam restore (B-team) done
03/20 Owl
  • Septum checkout (Michaels: Page when beam imminent & spectrometer ready)

also:

  • Initial look at low current cavity monitors (Zafar: Page when beam imminent & spectrometer ready)
  • Target alignment (Michaels)
  • VDC checkout (Michaels)
  • Quartz detectors checkout (McNulty, Wexler -- page when VDC tracks seen)
  • GEM checkout (Camsonne -- page when VDC tracks seen, if left dipole is operating)

All at 1-2 µA.
Scattered energy ~ beam energy = 1.063 GeV.
Quad settings:

  • Right arm:
    • Q1: dI/dP= 411.2474 Amps/GeV/c
    • Q2: dI/dP= 436.2014 Amps/GeV/c
    • Q3: dI/dP= 433.3897 Amps/GeV/c
  • Left Arm:
    • Q1: dI/dP= 419.8772 Amps/GeV/c
    • Q2: dI/dP= 435.6273 Amps/GeV/c
    • Q3: dI/dP= 434.9682 Amps/GeV/c

"Usual" polarity

done
03/20 Day Beam off & hall open 9:00 am

Quads repair; Compton install; GEM install; signals debugging. Leave sieves in. (Techs)

done
03/20 Swing
  • Close up hall
  • Benesch tuning (1/2 - 2 hours)
  • Verify quad polarities (Camsonne)
  • Cavity monitors basic function test (Zafar)
  • Low current cavity monitors setup (Musson, Zafar)
most done but need access to finish
3/21 Owl
  • Low current cavity monitors setup (Musson, Zafar)
  • Access for GEM installation (Camsonne)
most done but need access to finish
3/21 Day
  • Spectrometer checkout:
    • Quartz detectors checkout (McNulty, Wexler)
    • Lumi checkout (Mercado) (2 µA on Ta)
    • GEM checkout (Camsonne?)
  • A line tuning (Benesch)
  • Raster checkout
  • Access:
    • Low current cavities
    • Target position
    • Quartz
    • Scintillator alignment
    • LQ2
in progress
3/21 Swing
  • Low current cavity monitors setup (Michaels, Zafar)
  • Remove sieves
  • Initial look at sieve out data
  • Replace sieves
not done
3/22 Owl
  • Pointing measurement (Riordan)
  • Remove sieves
  • Repeat pointing measurements with no sieves
  • If done or unable to continue before 4 am page Luis Mercado to do lumi checks
  • After 4 am page Dustin McNulty for detector work
3/22 Day
  • Optics (Liyanage)Sieve OUT. NB Current limit 2 uA!
3/22 Swing
  • Optics continued, sieve IN. NB Current limit 2 uA! (Shift Crew)
3/23 Owl
  • Quartz detectors resolution studies (KK, Dustin, John W)
  • Lumi studies (Luis)
3/23 Day
  • Remove water target. (Target, Techs)
  • Reconfigure Moller cryo.
  • Beam studies ~ 2pm, study of helicity correlated position differences for spin flipper states. (Dalton, Rupesh, Reza)
3/23 Swing
  • Target pumpdown
3/24 Owl
  • Target pumpdown
3/24 Day
  • Target cooldown
3/24 Swing
  • Tune high current beam into Hall A
3/25 Owl
  • Commission lead target, 50 uA (Bob)
  • Lumis and oversampling tests (KK, Luis, Paul)
3/25 Day
  • Access to fix left dipole
3/25 Swing
  • Parity Quality commissioning (Kent, Rupesh, Luis, Dustin)
  • Beam monitor calibrations (Diancheng Wang, Xiaoyan Deng)
3/26 Owl
  • High Luminosity Detector Commissioning
3/26 Day
  • Moller Checkout
3/26 Swing
  • Moller Checkout
3/27 Owl
  • Establish Q2 measurement sequence (Dustin, Nilanga)
  • ARC energy measurement (Arun Saha)
3/27 Day
3/27 Swing
3/28 Owl
3/28 Day
3/28 Swing
3/29 Owl
3/29 Day
3/29 Swing
3/30 Owl
3/30 Day