Difference between revisions of "20181017-Radiation-Mtg"
From PREX Wiki
Jump to navigationJump to searchCiprian Gal (talk | contribs) (Created page with "Back to Main Page >> Radiation_Mtg previous meeting << >> following meeting == Logistic informatio...") |
Kent Paschke (talk | contribs) |
||
Line 11: | Line 11: | ||
== Agenda / Minutes == | == Agenda / Minutes == | ||
− | # | + | # Adam measured dose on 6" radius cut between target and collimator. [https://ace.phys.virginia.edu:80/HAPPEX/3552 elog:3552] |
− | #* | + | #* Dose about 1.6MGray on inner 1mm. |
+ | #* He will run Al and steel covers, and larger radius cut out. | ||
+ | # Victoria doesn't reproduce Adam's result on heating on collimator box flange. | ||
+ | #* She finds about 30 W (compared to about 70 W from Adam). | ||
+ | #* | ||
+ | #* | ||
+ | # Then talked about BMW | ||
+ | #* Are EPICS libraries on the vxWorks boards functioning? Can we expect them to work? (Victoria will check into this) | ||
+ | #* Walked through analysis steps, after having a beam modulation tree to work with. | ||
+ | #* Creation of slopes involves | ||
+ | #** correcting for "phase return" | ||
+ | #** fitting cycles (perhaps after averaging) | ||
+ | #** accumulating a full set of cycle correlation fits to create slopes (supercycle) | ||
+ | #** calculating correction slopes | ||
+ | #** outputting correlations and slopes from supercycle in tree, and or text file | ||
+ | #* The correction slopes we use will probably be averaged over some time period. | ||
+ | #* The quality of correction slopes can be checked using "residuals" of the modulation in the modulation data | ||
+ | #* Averaged corrections slopes will be applied in the analysis (post prompt? Perhaps by WAC?) using a macro to look up slopes and make correction | ||
+ | #** perhaps a macro would be made to provide an "alias" word for the corrected value for interactive use | ||
== Attendance == | == Attendance == | ||
=== Excused: === | === Excused: === |
Latest revision as of 16:37, 17 October 2018
Back to Main Page >> Radiation_Mtg
previous meeting << >> following meeting
Logistic information
BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 International toll number: 706 189 845 PARTICIPANT CODE: https://bluejeans.com/706189845
Agenda / Minutes
- Adam measured dose on 6" radius cut between target and collimator. elog:3552
- Dose about 1.6MGray on inner 1mm.
- He will run Al and steel covers, and larger radius cut out.
- Victoria doesn't reproduce Adam's result on heating on collimator box flange.
- She finds about 30 W (compared to about 70 W from Adam).
- Then talked about BMW
- Are EPICS libraries on the vxWorks boards functioning? Can we expect them to work? (Victoria will check into this)
- Walked through analysis steps, after having a beam modulation tree to work with.
- Creation of slopes involves
- correcting for "phase return"
- fitting cycles (perhaps after averaging)
- accumulating a full set of cycle correlation fits to create slopes (supercycle)
- calculating correction slopes
- outputting correlations and slopes from supercycle in tree, and or text file
- The correction slopes we use will probably be averaged over some time period.
- The quality of correction slopes can be checked using "residuals" of the modulation in the modulation data
- Averaged corrections slopes will be applied in the analysis (post prompt? Perhaps by WAC?) using a macro to look up slopes and make correction
- perhaps a macro would be made to provide an "alias" word for the corrected value for interactive use