# Chandan: Modified the MPDs and upgraded the firmware. The MPD library and Read-Out-List are modified to make debugging easy.
 +
# Chandan: New CAEN high voltage module (N1470) is tested with GEM detector. Digital patch panel is tested with SBU GEMs.
 +
# Chandan: To measure the efficiency of the GEM detectors large plastic scintillators are used in the cosmic stand.
 +
# Joey: Presented cosmic data, but source (Cs-137) data is having large occupancy.
 +
#* Seamus: Need to process the trigger signal with a pre-amplifier.
 +
#* Chandan: Source data is not very useful, try to acquire more cosmic data.
 +
#Chandan: We should start working on the ROL for counting DAQ.
 +
#* Cameron: There will be help for JLab staff.
 +
#Seamus: We should fit the six samples with a characteristic function to extract information from data.
 +
#Siyu: We have to decide the length of HDMI cables for SBS GEMs. Who will buy them?
 +
#Seamus: Probably PREX/CREX collaboration will buy this.
  
 
== Present ==
 
== Present ==
 
+
Seamus, Devi, Joey, Cameron, Ryan, Tao, Siyu, Chandan
 
===Excused===
 
===Excused===
 +
Dustin

Latest revision as of 17:05, 16 November 2018

Back to Main Page >> GEM_Meeting

Logistic information

 BlueJeans calling instructions:
 Toll-Free Number (U.S.&  Canada):  888-240-2560
 International toll number:         408-740-7256
 Bluejeans CODE:                  998 903 0149
 Bluejeans link: https://bluejeans.com/9989030149

Agenda

  • Chandan : SBU GEM update slides

Minutes

  1. Chandan: Modified the MPDs and upgraded the firmware. The MPD library and Read-Out-List are modified to make debugging easy.
  2. Chandan: New CAEN high voltage module (N1470) is tested with GEM detector. Digital patch panel is tested with SBU GEMs.
  3. Chandan: To measure the efficiency of the GEM detectors large plastic scintillators are used in the cosmic stand.
  4. Joey: Presented cosmic data, but source (Cs-137) data is having large occupancy.
    • Seamus: Need to process the trigger signal with a pre-amplifier.
    • Chandan: Source data is not very useful, try to acquire more cosmic data.
  5. Chandan: We should start working on the ROL for counting DAQ.
    • Cameron: There will be help for JLab staff.
  6. Seamus: We should fit the six samples with a characteristic function to extract information from data.
  7. Siyu: We have to decide the length of HDMI cables for SBS GEMs. Who will buy them?
  8. Seamus: Probably PREX/CREX collaboration will buy this.

Present

Seamus, Devi, Joey, Cameron, Ryan, Tao, Siyu, Chandan

Excused

Dustin