Difference between revisions of "DAQ Testing/20190118"
From PREX Wiki
Jump to navigationJump to searchLine 1: | Line 1: | ||
+ | Back to [[Main_Page|Main Page]] >> [[DAQ_Doc_Portal|DAQ Documentation Portal]] >> [[DAQ_Testing|DAQ Testing]] >> [[DAQ_Commissioning_Notes|DAQ Commissioning Notes]] | ||
+ | |||
+ | [[DAQ_Testing/20190115|Previous Day of Testing]] << >> [[DAQ_Testing/20190121|Next Day of Testing]] | ||
+ | |||
+ | January 15th, 2019 | ||
+ | Testers: Cameron Clarke, Tao Ye, Bob | ||
+ | |||
+ | == Goals == | ||
+ | |||
+ | * Do pedestal studies with a battery on the HRSs | ||
+ | |||
+ | == Pedestal Testing == | ||
+ | |||
Using batteries to look for pedestal noise floor, drift, or helicity correlated pickup | Using batteries to look for pedestal noise floor, drift, or helicity correlated pickup | ||
* Run 1032 - failed | * Run 1032 - failed |
Revision as of 16:20, 18 January 2019
Back to Main Page >> DAQ Documentation Portal >> DAQ Testing >> DAQ Commissioning Notes
Previous Day of Testing << >> Next Day of Testing
January 15th, 2019 Testers: Cameron Clarke, Tao Ye, Bob
Goals
- Do pedestal studies with a battery on the HRSs
Pedestal Testing
Using batteries to look for pedestal noise floor, drift, or helicity correlated pickup
- Run 1032 - failed
- Run 1033 - Battery (1.6 V) plugged into RHRS first ADC, channel 7 (index 7, 8th channel) - 5300 events at 30 Hz flip rate, 500 us Tsettle time (scalers and synch monitor are now invalid - were set for 240 Hz and 160 us Tsettle timing)
- Run 1034 - Battery (1.6 V) plugged into RHRS second ADC, channel 4 - 5300 events (I may have accidentally moved lumi signal in channel 1 to 2, either way, its in 2 now)
- Run 1035 - Battery (1.6 V) plugged into LHRS only ADC, channel 7 -