February 6th, 2019 Testers: Cameron Clarke, Devi Adhikari, Paul King
Goals
- Establish standard DAQ initialization
- Take pedestal noise floor calibration runs for updated SAM cabling configuration
- Check on 2 ET sleep delay
- Check on Chris Cuevas' VQWK fixing approach - lets meet next wednesday to go over this, first resurrect the TEDf test stand
Establish Standard DAQ Initialization and test SAMs and ET problems
Paul King set up a new standardized way of initializting QWeak ADCs using the g0inj.flags files that the injector already uses (instead of a boot script or Green Monster initialization).
Continuing from yesterday - I put the vqwk gate through the from HEL signal to LHRS - fixed it now:
- Run 1199 - Worked in Hardware DAQ, but all nsamps=0
- Run 1200 - same problem
- Run 1201 - Paul reverts to prior CRL edition
- Run 1202 and 1203 - I test new ET bridge code, works, but et_open for remote 64 bit ET system still has a bug, Carl Timmer gave me a bug fix to implement that will tell a remote ET session operating on a local machine to check for ET existence without segfaulting
- Run 1204 - With ET 32 and 64 dead the EB fails
- Run 1205 - With ET 64 dead it never works
- Stop using CODA to test ET problems - just use 2 ETs by themselves with ETbridge executed individually
- Run 1206 - CH config test - checking g0inj.flgs refactor for clean data
- Works, but LHRS is off/disconnected
- LHRS ethernet connection had come out
- Run 1207 - Testing Prex_ALL config and SAM noise floor data with HV on and proper nsamp
- Worked, short run, everything is fine!
- Run 1208 and 1209 - Long SAM runs, HV on
- Run 1210 - Long SAM run, HV off
- Run 1211 - restore injector mode
HALOG entry, and another
To Do
- Restore CH Helicity Control Board
- Replace Vqwk1 in CH DAQ
- Set up vqwk gate's veto signal to go to CH and HRS crates
- Set up HAPPEX ADC gate window and/or setHAPTB command into .flags file?
- Set up SIS3801 scaler veto to be intelligent and run a new patch panel cable for these