Difference between revisions of "Full Shift Checklist"
(Created page with "Shift leader Target operator Analysis expert Shift (day, swing, or owl) Is alarm handler running on hacweb7? Is the volume up on hacweb7? (both hardware and software) Beam E...") |
|||
Line 1: | Line 1: | ||
− | Shift leader | + | * Shift leader |
− | Target operator | + | * Target operator |
Analysis expert | Analysis expert | ||
Shift (day, swing, or owl) | Shift (day, swing, or owl) |
Revision as of 10:57, 12 June 2019
- Shift leader
- Target operator
Analysis expert Shift (day, swing, or owl)
Is alarm handler running on hacweb7? Is the volume up on hacweb7? (both hardware and software)
Beam Energy (GeV) Beam current (µA) Downstream raster (B) on? Yes/No Raster size (x:y mm, see log 3654466 )? Fast feedback on? Yes/No Beam Position Monitor X/Y (mm) A Beam Position Monitor X/Y (mm) E (BPM B in Hall A Tools) BCM temperature (K) (PV, PS, Thermocouple) If these differ by +/-.5 from (110.0,110.0,115.0) contact RC and halog Arc energy NMR locked? ( (Goto ARC or the "Field Management Screen", and verify if the box locked is ON/OFF)) VESDA System OK? (VESDA is the smoke/fire detection and alarm system. Check the Hall A VESDA Console on the wall beside the door to the compter room
Current Target Argon pressure (psi) Ethane pressure (psi) CO2 pressure (psi) Visual Hall Inspection OK? Truck ramp door closed ( use the camera to see the door from mirror)? Septum current (A) and polarity? Upstream/downstream corrector currents (A) ?
Left Arm momentum (GeV) Left Arm Q1, Q2, D, Q3 regulartors on (yes/no, ask experts)? Left Arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen) Left Arm NMR OK? Yes/No Left Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G) Left Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G) Left Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G) Left Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G) Is Left VDC gas flow (top/bottom) on? Left VDC HV on (top/bottom)? VDC thresholds (All 4 values should be 3.0 V, yes/no) ? Left Cerenkov HV on? Left Pion rejector HV on? Left s0/s2m HV on (s0 may be off for production, check with expert)? Check online plots (y/n)? -LHRS
Right arm momentum (GeV) Right Arm Q1, Q2,D,Q3 regulartor on? (yes/no) Right arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen) Right Arm NMR OK? Yes/No Right Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G) Right Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G) Right Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G) Right Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G) Is Right VDC gas flow (top/bottom) on? Right VDC HV on (top/bottom)? Right Cerenkov HV on? Right Pion rejector HV on? Right s0/s2m HV on? Right SCIFI HV off (should be off during production runs, y/n)? S3 HV off (ch 6 of SCIFI HV GUI, should be off for production)? Check online plots (y/n)? -RHRS
Latest run type (Test, Physics,..)
Is the auto replay script running (ask the analysis expert)?
Is the APEX run list (in a white binder) completed?
Please attach the left/right HV and Scalers Screenshots to the shift report
Time of beginning of latest run (RHRS)
Latest run number
Dead time (%)
Beamtime accounting table submitted?
Empty drip tray and place mug under spout on coffee maker