== Beamline instrumentation calibration == | == Beamline instrumentation calibration == | ||
− | #Check the following has been performed | + | # Check the following has been performed |
#* 50uA-70uA beam current, through Compton (backgrounds on fingers and Compton photon detector) with no target | #* 50uA-70uA beam current, through Compton (backgrounds on fingers and Compton photon detector) with no target | ||
#* Establish 4x4 raster. Insert lead target. | #* Establish 4x4 raster. Insert lead target. | ||
#* Set Detector and SAM voltages (Dustin M) | #* Set Detector and SAM voltages (Dustin M) | ||
− | #Check Conditions OK | + | # Check Conditions OK |
#*collimator water | #*collimator water | ||
#*thermocouple temperatures | #*thermocouple temperatures | ||
Line 11: | Line 11: | ||
#*ion chamber stability | #*ion chamber stability | ||
− | #Setup Locks (these are necessary for main detectors and SAM calibration) | + | # Setup Locks (these are necessary for main detectors and SAM calibration) |
#*Slow Target Lock on 4A, 4E (jmenu->"slow locks"-> Orbit Locks Expanded View -> HallATGT) | #*Slow Target Lock on 4A, 4E (jmenu->"slow locks"-> Orbit Locks Expanded View -> HallATGT) | ||
#* Fast feedback for HallA on (iocse9) | #* Fast feedback for HallA on (iocse9) | ||
Line 17: | Line 17: | ||
#* Should HallAMolLock be on? | #* Should HallAMolLock be on? | ||
− | #Coordinate | + | # Coordinate |
#* Should Compton and Moller DAQ be running during calibration? | #* Should Compton and Moller DAQ be running during calibration? | ||
#* Dustin and Devi examining SAMs and Detectors with online analyzer during calibration | #* Dustin and Devi examining SAMs and Detectors with online analyzer during calibration | ||
#* Juan Carlos/Amali/Adam monitor Compton background rates and run the DAQ? | #* Juan Carlos/Amali/Adam monitor Compton background rates and run the DAQ? | ||
− | #Calibration Procedure A: with UNSER | + | # Calibration Procedure A: with UNSER |
#*start at 70uA for 1min (scandata1==value in BCM0l02) | #*start at 70uA for 1min (scandata1==value in BCM0l02) | ||
#*beam off | #*beam off | ||
Line 33: | Line 33: | ||
#*repeat for 65uA,60uA,55uA,50uA,40uA,30uA,20uA,10uA | #*repeat for 65uA,60uA,55uA,50uA,40uA,30uA,20uA,10uA | ||
− | #Calibration Procedure B: with pre-calibrated Hall BCM (analog upstream bcm) | + | # Calibration Procedure B: with pre-calibrated Hall BCM (analog upstream bcm) |
#*start at 70uA for 1min (scandata1==value in BCM0l02) | #*start at 70uA for 1min (scandata1==value in BCM0l02) | ||
#change current to 75uA | #change current to 75uA | ||
Line 42: | Line 42: | ||
#*repeat for 65uA,60uA,55uA,50uA,40uA,30uA,20uA,10uA | #*repeat for 65uA,60uA,55uA,50uA,40uA,30uA,20uA,10uA | ||
− | #Calibration Procedure C: for BPMs (Compton bpms not yet calibrated) | + | # Calibration Procedure C: for BPMs (Compton bpms not yet calibrated) |
#*at 70uA, set gains off for iocse9,iocse10 (Hall) iocse11,iocse12,iocse19,iocinse4 (Inj) | #*at 70uA, set gains off for iocse9,iocse10 (Hall) iocse11,iocse12,iocse19,iocinse4 (Inj) | ||
#*rperform Calibration Procedure B with pre-calibrated Hall BCM | #*rperform Calibration Procedure B with pre-calibrated Hall BCM |
Revision as of 09:43, 25 June 2019
Beamline instrumentation calibration
- Check the following has been performed
- 50uA-70uA beam current, through Compton (backgrounds on fingers and Compton photon detector) with no target
- Establish 4x4 raster. Insert lead target.
- Set Detector and SAM voltages (Dustin M)
- Check Conditions OK
- collimator water
- thermocouple temperatures
- radiation monitors
- ion chamber stability
- Setup Locks (these are necessary for main detectors and SAM calibration)
- Slow Target Lock on 4A, 4E (jmenu->"slow locks"-> Orbit Locks Expanded View -> HallATGT)
- Fast feedback for HallA on (iocse9)
- If beam is going through Compton, HallAComLock should probably be on
- Should HallAMolLock be on?
- Coordinate
- Should Compton and Moller DAQ be running during calibration?
- Dustin and Devi examining SAMs and Detectors with online analyzer during calibration
- Juan Carlos/Amali/Adam monitor Compton background rates and run the DAQ?
- Calibration Procedure A: with UNSER
- start at 70uA for 1min (scandata1==value in BCM0l02)
- beam off
- wait for 5sec(for unser to equilibrate), take unser pedestal data point for 30sec (scandata1=0)
- beam on at 75uA
- check slow target lock is in position
- check FFB on for HallA
- check no bpms are saturated on iocse9
- wait for 5sec(for unser to equilibrate), take next data point for 1min
- repeat for 65uA,60uA,55uA,50uA,40uA,30uA,20uA,10uA
- Calibration Procedure B: with pre-calibrated Hall BCM (analog upstream bcm)
- start at 70uA for 1min (scandata1==value in BCM0l02)
- change current to 75uA
- check slow target lock is in position
- check FFB on for HallA
- check no bpms are saturated on iocse9
- take next 1min data point
- repeat for 65uA,60uA,55uA,50uA,40uA,30uA,20uA,10uA
- Calibration Procedure C: for BPMs (Compton bpms not yet calibrated)
- at 70uA, set gains off for iocse9,iocse10 (Hall) iocse11,iocse12,iocse19,iocinse4 (Inj)
- rperform Calibration Procedure B with pre-calibrated Hall BCM
- Beamline instrumentation calibration 0.5 shift Caryn P,
- Current ramp for BPM/BCM calibrations and detector pedestals detailed plan
- Initial production condition test 0.25 shift Caryn P,
- detector and SAM widths
- regression sensitivities
- beam noise and asymmetry check
- collimator water and thermocouple temperatures,
- radiation monitors and ion chamber stability
- Width studies 0.5 shift KK,
- detector and SAM widths, targets, shutters, etc
- deinstall shutters at conclusion of test