Difference between revisions of "Beam Modulation"

From PREX Wiki
Jump to navigationJump to search
Line 25: Line 25:
 
Task for the analysis shift expert:
 
Task for the analysis shift expert:
 
  For each run,  
 
  For each run,  
* Check the online plot ( the top plot on the BMW plot page), we should see all 7 coils (colorful bars) at least for one super cycle (one bunch). If not, please call Ye: 803-553-3570  
+
* Check the online plot ( the top plot on the BMW plot page), we should see all 7 coils (colorful bars) at least for one super cycle (one bunch). If not, check the beam trips, if this run has a lot of beam trips, then check the other more stable runs. If you still miss one or more coils,  then please call Ye: 803-553-3570.
* Check the online plot ( on the BMW Cycle page ), if you could't see the plots. just
+
* Check the online plot ( on the BMW Cycle page ).
 
 
  
 
* [[BMOD | BMOD meetings]]
 
* [[BMOD | BMOD meetings]]
 
* Beam Modulation Documentation [[Beam_Mod_Portal | Portal]]
 
* Beam Modulation Documentation [[Beam_Mod_Portal | Portal]]

Revision as of 16:46, 14 July 2019

In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.

PREX Main << Expert Tools

How to Run Beam Modulation

  • First, make sure Coda is running
  • You need to be logged in apar account on adqa3:
    •  ssh apar@adaq3 
  • Go to directory:
    •  cd /adaqfs/home/apar/vowen/BMWClient/PyGreenMonster/ 
  • Run beam modulation code:
    •  python3 ProductionModulation_Pause10Min.py 
    1. Beam modulation will automatically run for 7 days
    2. In order to quit beam modulation
      •  control+c 
        to crash out of the beam modulation program.
      •  python3 gm_bmw_clearall.py 
        to clean up the DAQ records and release the EPICS FFB pause states.

Modulation online plots

modulation coil plot Task for the analysis shift expert:

For each run, 
  • Check the online plot ( the top plot on the BMW plot page), we should see all 7 coils (colorful bars) at least for one super cycle (one bunch). If not, check the beam trips, if this run has a lot of beam trips, then check the other more stable runs. If you still miss one or more coils, then please call Ye: 803-553-3570.
  • Check the online plot ( on the BMW Cycle page ).