* Major issue: BCM Upstairs Black box noise on AN_US | * Major issue: BCM Upstairs Black box noise on AN_US | ||
− | == Production Run List (status at | + | == Production Run List (status at 6pm 7/17/2019) == |
− | * | + | * Cut first 30k events out: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3398_000/run3398_000_all.pdf 3398] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3399_000/run3399_000_all.pdf 3399] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3400_000/run3400_000_all.pdf 3400] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3401_000/run3401_000_all.pdf 3401] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3402_000/run3402_000_all.pdf 3402] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3403_000/run3403_000_all.pdf 3403] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3404_000/run3404_000_all.pdf 3404] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3405_000/run3405_000_all.pdf 3405] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3406_000/run3406_000_all.pdf 3406] |
− | * | + | * Good: [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-17/run3407_000/run3407_000_all.pdf 3407] |
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == |
Revision as of 20:35, 17 July 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.
PREX Main << Weekly Analysis Coordinator << Instructions
July 17 2019
- WAC = Cameron Clarke
- Slug 3
- Beam Status
- OWL had ~7 hours of beam, with some sketchy BPM noise and clear BCM DD problems
- Major issue: BCM Upstairs Black box noise on AN_US
Production Run List (status at 6pm 7/17/2019)
- Cut first 30k events out: 3398
- Good: 3399
- Good: 3400
- Good: 3401
- Good: 3402
- Good: 3403
- Good: 3404
- Good: 3405
- Good: 3406
- Good: 3407
Non-Production Runs and Bad Runs
- Calibration (BPM): 3395 - HALOG
- Calibration (BCM): 3396 - HALOG
- Calibration (Restore Beam): 3397 - HALOG
Pedestal/Calibrations Updates
- Tao's Pedestal Update
- Using: prexCH_beamline_pedestal.3396.map for 50uA runs from slug 3 onward - new BPMs in ARC need attention
- Using: prexCH_beamline_pedestal.3395.map - use it as a template pedestal map for 70 uA runs.
- I've taken prexCH_beamline_pedestal.3396.map and placed it in the prexCH_beamline_pedestal.3390-.map
- Caryn's Hall C and cav4cQ pedestals (3373 and 3378 respectively)
Issues
- Tuning 3397 - HALOG
- Charge Feedback glitch: non-fatal QW Feedback process fighting with Analysis Minder - HALOG, HALOG
- OPS FFB on: for a few minutes of run 3398 - HALOG
- Strange beam motion at beginning of 3398 - HALOG
- BCM Noise/phase lag question: Begins run 3400, varies, investigated on scope, looks like BCM black box issue - HALOG, Sakib noted, Victoria noted
- Looked at on a scope with Tune Beam and changing all cables isolates it to a electronics/hardware issue in the Upstairs black box, not downstairs.
- This will need to be fixed, but probably the data is fine.
- BPMs have strange noise, especially 4eY: Beings run 3399 - HALOG
- Compliment BPMs don't have this noise (anecdotal), and their DDs w.r.t. normal BPMs is noticeable - HALOG, HALOG 2
- At Left 1 is - w.r.t. At Left 2, and this isn't mirrored in Right - Devi says this is beam related, and HVs were off...
- Main Detectors R vs. L correlations shift in time? -> Kent says this is normal and has to do with beam motion sensitivity - HALOG
- LHRS Dipole moved a bit - HALOG, [1]
Other Status Updates
- Beam Mod is OK - HALOG
- Aq is working, nothing more than ~0.2 ppm mean charge asymmetry over a given run, many sub 0.02 ppm - See Online Plots
- SAM pedestals made SAM 8 look like a negative signal, was spurious, Devi is fine with it