Difference between revisions of "WAC Notes July 26 2019"
From PREX Wiki
Jump to navigationJump to searchLine 25: | Line 25: | ||
Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug14-Left/y_postPanPlots_slug14-Left.pdf Slug 14, IHWP In, FFB on always] | Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug14-Left/y_postPanPlots_slug14-Left.pdf Slug 14, IHWP In, FFB on always] | ||
** '''Since we are using bcm_dg_ds, the width in the bcm asymmetry is 2X of what we had with bcm_an_ds''' | ** '''Since we are using bcm_dg_ds, the width in the bcm asymmetry is 2X of what we had with bcm_an_ds''' | ||
− | + | ** '''We used the same, bcm_dg_ds, bcm in slug13 also, where the Aq width was ~1.5X of what we had with bcm_an_ds''' | |
* Suspicious - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3649_000 run3649] | * Suspicious - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3649_000 run3649] | ||
** Short run with many beam trips | ** Short run with many beam trips |
Revision as of 08:39, 27 July 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions
WAC Notes July 25 2019 << >> WAC Notes July 27 2019
July 26 2019
Daily Meeting BlueJeans
Production Run List
Start Slug 14, IHWP In, FFB on always
- Since we are using bcm_dg_ds, the width in the bcm asymmetry is 2X of what we had with bcm_an_ds
- We used the same, bcm_dg_ds, bcm in slug13 also, where the Aq width was ~1.5X of what we had with bcm_an_ds
- Suspicious - run3649
- Short run with many beam trips
- Caryn says "attempting to go to production but having some FFB issues"
- Suspicious - run3650
- BPM11 saturated
- Suspicious - run3651
- BPM11 saturated
- Good - run3652
- Good - run3653
- Good - run3654
- Good - run3655
- Good - run3656
Non-Production Runs and Bad Runs
- Test run3637
- Test run3638
- Test run3639
- Test - run3640
- This run was taken during collimator scan
- Aq widths are too large
- Test - run3641
- Aq widths are too large (>200ppm)
- Started with 1uA checking position then go to 70uA
- Really a test run
- Test run3642
- Test run3643
- Musson injects 10uA fake signal into digital system after new chassis added
- Test run3644
- Target Trouble Shooting
- Test run3647
- Attempting to production but some Feedback issue run3648
Pedestal/Calibrations Updates
Issues
Other Status Updates
- Accumulated charge =
- bcm_dg_ds pedestal map has been updated HAPLOG
- started burpcut since slug13