Difference between revisions of "WAC Notes July 25 2019"
From PREX Wiki
Jump to navigationJump to searchLine 29: | Line 29: | ||
** Mini-run 0 had too large detector widths->'''Fixed after bad_event_cut''' | ** Mini-run 0 had too large detector widths->'''Fixed after bad_event_cut''' | ||
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3626_000 run3626] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3626_000 run3626] | ||
− | * | + | * NeedCut - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3629_000 run3629] |
+ | ** Couldn't find any obvious cut region | ||
** Aq mean is large | ** Aq mean is large | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3630_000 run3630] |
** Detector widths are fluctuating between mini-runs. | ** Detector widths are fluctuating between mini-runs. | ||
** First run with detector width started increasing | ** First run with detector width started increasing | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3631_000 run3631] |
** Detector widths become worse | ** Detector widths become worse | ||
** Beam position change | ** Beam position change | ||
** Beam current fluctuating | ** Beam current fluctuating | ||
** Normalized detector yield is decreasing over time | ** Normalized detector yield is decreasing over time | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-26/run3632_000 run3632] |
** Regressed detector widths are even higher | ** Regressed detector widths are even higher | ||
** Normalized detector yield is decreasing over time | ** Normalized detector yield is decreasing over time | ||
** Regressed detectors are correlated | ** Regressed detectors are correlated | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-26/run3633_000 run3633] |
** Normalized detector yield is increasing over time (opposite to run3632) | ** Normalized detector yield is increasing over time (opposite to run3632) | ||
** Regressed detectors are correlated | ** Regressed detectors are correlated | ||
** Regressed detector widths are larger | ** Regressed detector widths are larger | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3634_000 run3634] |
** Normalized detector yield is increasing over time (opposite to run3632) | ** Normalized detector yield is increasing over time (opposite to run3632) | ||
** Regressed detectors are correlated | ** Regressed detectors are correlated | ||
** Regressed detector widths are larger | ** Regressed detector widths are larger | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3635_000 run3635] |
** Normalized detector yield is increasing over time (opposite to run3632) | ** Normalized detector yield is increasing over time (opposite to run3632) | ||
** Regressed detectors are correlated | ** Regressed detectors are correlated | ||
** Regressed detector widths are larger | ** Regressed detector widths are larger | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3636_000 run3636] |
** Long beam trip during the run | ** Long beam trip during the run | ||
** Normalized detector yield is decreasing again | ** Normalized detector yield is decreasing again |
Revision as of 15:06, 3 August 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions
WAC Notes July 24 2019 << >> WAC Notes July 26 2019
July 25 2019
Production Run List
Start Slug 13, IHWP OUT Flip Right, FFB on always
- Since we are using bcm_dg_ds, the width in the bcm is ~1.5X of what we used to have with bcm_an_ds3
- Good - run3622
- Good - run3623
- Good - run3624
- Good - run3625
- Mini-run 0 had too large detector widths->Fixed after bad_event_cut
- Good - run3626
- NeedCut - run3629
- Couldn't find any obvious cut region
- Aq mean is large
- Good - run3630
- Detector widths are fluctuating between mini-runs.
- First run with detector width started increasing
- Good - run3631
- Detector widths become worse
- Beam position change
- Beam current fluctuating
- Normalized detector yield is decreasing over time
- Good - run3632
- Regressed detector widths are even higher
- Normalized detector yield is decreasing over time
- Regressed detectors are correlated
- Good - run3633
- Normalized detector yield is increasing over time (opposite to run3632)
- Regressed detectors are correlated
- Regressed detector widths are larger
- Good - run3634
- Normalized detector yield is increasing over time (opposite to run3632)
- Regressed detectors are correlated
- Regressed detector widths are larger
- Good - run3635
- Normalized detector yield is increasing over time (opposite to run3632)
- Regressed detectors are correlated
- Regressed detector widths are larger
- Good - run3636
- Long beam trip during the run
- Normalized detector yield is decreasing again
- Regressed detector widths are larger
Non-Production Runs and Bad Runs
- Test - run3628
Pedestal/Calibrations Updates
Issues
- There were many pedestal and event cut problems. From now on, when an event cut isn't absolutely necessary it should be removed - see japan source code for reference of cuts here
- The BCM appears to be falling apart. We are fixing it and running slug 12 on BCM DG DS in the meantime.
- BPM 4ec had intermittant problems (iocse10 has issues) and so we are regressing with 4e again. BPM 11X is ok and stays in regression.
- Increase in Detector widths and Collimator temperature HALOG COLLIMATOR HALOG
- Increase in collimator temperature and raising neutron dose HALOG
- The increase in detector widths started from late Swing Shift HALOG
- Cavity BPM lock change HALOG