Difference between revisions of "WAC Notes January 31 2020"

From PREX Wiki
Jump to navigationJump to search
Line 56: Line 56:
  
 
* There are some issues in the injector, resulting in large bcm asym in two runs (6086, 6087)
 
* There are some issues in the injector, resulting in large bcm asym in two runs (6086, 6087)
* quite large bcm asym (324 ppm) in run 6099, don't know why. the asym in injector asym_bpm2i01WS is quite large: -8.67 compare to grand average value (
+
* quite large bcm asym (324 ppm) in run 6099, don't know why. the asym in injector asym_bpm2i01WS is quite large: -8.67 compare to grand average value (< 5ppm)
  
 
== Updates ==
 
== Updates ==

Revision as of 16:37, 1 February 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes January 30 2020 << >> WAC Notes February 1 2020

January 31 2020

Daily Meeting BlueJeans

continue slug 121 on January 29:

Production Run List - Slug 121 - IHWP OUT - Flip-RIGHT - Production


start the new slug at ~ 7 am

Production Run List - Slug 122 - IHWP IN - Flip-RIGHT - Production

continue slug 122 on February 1

Non-Production Runs and Bad Runs

Pedestal/Calibrations Updates

BeamMod Commissioning calibration runs: 6076 - 6084

Issues

  • There are some issues in the injector, resulting in large bcm asym in two runs (6086, 6087)
  • quite large bcm asym (324 ppm) in run 6099, don't know why. the asym in injector asym_bpm2i01WS is quite large: -8.67 compare to grand average value (< 5ppm)

Updates