August 4th, 2020 Tester: Cameron Clarke
Replacing VQWK number 025 from L:HRS _0_3 bad channel
To make these plots I have used the DAQ_Checkout.conf decoding configuration (for the CH_INJ CODA config) and used the panguin macro QualityAssurance/testChannels.cfg
- Run 7536 - https://logbooks.jlab.org/entry/3820478
Checking out all ADC modules
Using the RampAll config (rampdac16 setting in CH crate cedit config)
- Run 7537 - Looks good by eye, if interested see PDFs in ~/cameronc/DAQ-calibration/CREX-August-Restart/
- Run 7538-7544 : remaining 7 ADCs in CH crate, all appear good
- Run 7545 - added rampdac16 to L and RHRS in CEDIT - test run, works