WAC Notes August 12 2020
From PREX Wiki
Revision as of 03:37, 13 August 2020 by Cameronc (talk | contribs) (Created page with "{| cellpadding=5 style="margin:7px 30px 0 30px; <!-- --> float:right; border:1px solid #AA6633" |- bgcolor="#fbfeff" |- |Documentation |- | HOW TOs | HOW TOs for shif...")
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes August 11 2020 << >> WAC Notes August 13 2020
August 12 2020
Daily Meeting BlueJeans
Production Run List - Slug 187 - IHWP IN - Flip-RIGHT - Production/Recommissioning
- Suspicious - Run 7657 - First run after long down for hall work, injector work, and FFB recommissioning. There is clearly still some noise in the Y bpms, but not as much as yesterday. Really bad BPM jitter and noise, causing 5000ppm raw RHRS noise and inadequate regression... suspicious. Place a 12X cut at >-0.5
- Good - Run 7658 - Excursion, cut out 60k-80k for X and E BPMs. OPS changed gang phase which fixed up bad noise and beam instability issues. There is a large excursion at the beginning, but probably benign
- Good - Run 7660 - BPM Ys are still broad while FFB is on, but looks better now
- Good - Run 7661 - looks good
Non-Production Runs and Bad Runs
- Junk - Run 7659 - During alignment check with low current on Ca48
Issues
- FFB issues at the beginning of the shift, but Gang Phase adjustments seem to get it down to a manageable level
- There was concern over the RHRS having worse RMS regressed asymmetry
- There is a ~30 ppm worse RHRS width, due to LHRS having 3mm more acceptance of inelastics
- There was a false alarm of high width due to misusing 4aX BPM instead of 1X in the regressed histogram in panguin... oops!
- Devi took an alignment run (with no dpp...) and sees everything is almost exactly as it was in March
Updates
- Detectors are in exactly the same spots and conditions as in March
- Pedestals need to be obtained in a few days and these runs reprompted