Task-List-main
From PREX Wiki
Task List, Preparing for 2018 Run
Simulation
Base design, v3 Benchmarks. <<Complete by March 16>>
- Need new benchmarks (accounting for updated geometry (dump, HRS) and SAMS
- for PREX-I, HAPPEX-II, PREX-2, CREX (and others?)
- on HRS detectors, under HRS detectors, Hall Lid or Hall Wall total ("whole hall"), and Hall Lid skyshine estimates
- prex2-v3:
- prex-2 dump, with shield
- no SAMS, or alternative SAMs?
- crex2-v3:
- (same with 48Ca target and 2.1 GeV)
- prex1-"??name??"
- PREX-I collimator
- PREX-I chamber? (not as important)
- PREX-I dump (with KW correction)
- no HDPE, no SkyshineShield
- Full size HRS det and structure, match prex2
- FULL PREX-I SAMS
- HAPPEX-II - ??name??
- HAPPEX-II collimator (same as PREX-I?)
- PREX-I dump (with KW correction)
- 3.2 GeV, 20cm LH2
- PREX-I chamber (not as important)
- no HDPE, no SkyshineShield
- Full size HRS det and strucutre, match prex2 sim
- FULL PREX-I SAMS
- PV-DIS?
- HAPPEX-3?
- TRITIUM (11 GeV)?
- DVCS?
Geometry, Next iteration. <<Complete by April 6>>.
- realistic gaps around dump shield
- target chamber
- collimator chamber to match design
- HDPE around target to match design
- modified SAM design?
O-Ring damage:
- Plots:
- E-weighted, electron only plots from beamline det an o-ring det
- tables to arrive at integrated grays
- hall-lid det x0/y0 plot to show enhancement from full SAMS
- get info on O-ring from engineering. (material, lifetime expectations, also when did this appear?)
- Full base design (Feb18), but w/o dump shield
- Use Al around O-ring
- No SAMS
- PREX-I SAMS
- test 1/2 size O-ring (PREX) (PREX-I SAMS)
- Done, but dumb results. Compare 1/2 size O-ring with 1/2 of full size O-ring.
- test no material around O-ring (PREX) (PREX-I SAMS)
- CREX
- No SAMS
- PREX-I SAMS
- check beam-offset run
- Use Al around O-ring
- Results for alternative SAM configs
- Final estimate use full base design (Feb18), including dump shield
- PREX-2
- CREX
SAM redesign:
- calculate rates vs angle
- calculate doses vs angles
- get details on beer can, make default design including welding
- Attempt final design
Activation Estimation
- Downstream septum beampipe flange, contact dose
- Downstream septum beampipe flange, whole body dose
- CREX activation estimates
- HDPE activation.
- DUST ACTIVATION?
HDPE parameters:
- Total / peak radiation dose. Damage?
- spec non-flamable HDPE, or devise fireproofing
Thermal Neutrons:
- count thermal/near thermal (<1eV rate), assume 8MeV / n energy release, compare to E&M power
- plot sources of thermal neutrons in hall, using hall-lid and HRS-platform detectors
- consider effect of 5% boron
- calculate thermal neutrons at Compton polarimeter
Analysis Chain
DAQ / Slow Controls
Beam Modulation System
Detector Stack
GEMs
Integrating Detectors
Detector Mounting Hardware
Polarized Source
Documentation
Formal
Collaboration